PowerSeries
PC1616/PC1832/PC1864 version 4.2 NA
Installation Guide
WARNING: This manual contains information on limitations regarding product use and function and infor-
mation on the limitations as to liability the manufacturer. The entire manual should be carefully read.
Vue de la page 0
1 2 3 4 5 6 ... 67 68

Résumé du contenu

Page 1 - PowerSeries

PowerSeries PC1616/PC1832/PC1864 version 4.2 NAInstallation GuideWARNING: This manual contains information on limitations regarding product use and fu

Page 2 - Table of Contents

PowerSeries - PC1616/PC1832/PC18648Section 3: ProgrammingThis section provides the information necessary to program all required features for a basic

Page 3 - Installation

Section 3: Programming9The Armed and Ready lights indicate programming status:Armed Light ON Panel waiting for 3-digit section numberIf in module prog

Page 4 - Burglary Zone Wiring Chart

PowerSeries - PC1616/PC1832/PC186410Section 4 – Programming DescriptionsThe following is a brief description of the features and options available in

Page 5 - PC1616/1832/1864

Section 4 – Programming Descriptions11Section [005] System TimesAfter entering Section [005], enter the 2-digit subsection number for the desired part

Page 6 - DC - 14VDC

PowerSeries - PC1616/PC1832/PC186412Section [012] Keypad LockoutThe system can be programmed to ‘lockout’ keypads if a series of incorrect user or ins

Page 7 - Section 2: User Commands

Section 4 – Programming Descriptions13Section [014] Second System Option CodeSection [015] Third System Option Code[5] ON: auto-arming schedules (Prog

Page 8 - Master Code all functions

PowerSeries - PC1616/PC1832/PC186414Section [016] Fourth System Option CodeSection [017] Fifth System Option CodeSection [018] Sixth System Option Cod

Page 9

Section 4 – Programming Descriptions15Section [019] Seventh System Option CodeSection [020] Keypad Zone AssignmentEnter the two-digit zone number to b

Page 10 - Section 3: Programming

PowerSeries - PC1616/PC1832/PC186416Section [023] Tenth System Option CodeSection [030] Fast Loop ResponseThis section is used to determine the Loop R

Page 11

Section 4 – Programming Descriptions17Keypad zones and zone expanders will always follow Section [013].When Zone Types (Section [001] to [004]) are pr

Page 12

Table of ContentsSection Description Page11.11.21.31.41.51.61.71.81.91.10Installation & Wiring...

Page 13 - Section [007] Master Code

PowerSeries - PC1616/PC1832/PC186418Section [170] PGM Output TimerProgram the time, in seconds, PGM outputs programmed to follow the PGM Output Timer

Page 14 - Section [012] Keypad Lockout

Section 4 – Programming Descriptions19different format, this account number will be used for all events that are not partition specific (for example,

Page 15 - ][5] command

PowerSeries - PC1616/PC1832/PC186420Section [379] Periodic DLS Time of Day Programs the time the system will auto-call DLS. Program 4 digits – [HH][MM

Page 16

Section 4 – Programming Descriptions21Section [383] Fourth Communicator Option CodeSection [389] T-Link Fault Check TimerProgram the period of time (i

Page 17 - ][3] menu access

PowerSeries - PC1616/PC1832/PC186422Section [404] Panel Identification CodeProgram the 6-digit Panel Identification Code. This code is used by the dow

Page 18

Section 4 – Programming Descriptions23PGM Output Option [31]PGM Output Option [32]PGM Output Option [29] and [35]-[41]Section [551] to [564] PGM Parti

Page 19

PowerSeries - PC1616/PC1832/PC186424Section [601] to [608] Additional Reporting Codes Program the reporting code for all events to be transmitted. For

Page 20 - ] key press

Section 4 – Programming Descriptions25Section [703] Delay Between Dialing AttemptsProgram the time the panel will wait between dialing attempts to tra

Page 21

PowerSeries - PC1616/PC1832/PC186426Section [904]: Wireless Placement TestEnter Section [904] followed by the 2-digit number of the wireless zone to t

Page 22

Section 5: Programming Work Sheets27Section 5: Programming Work Sheets5.1 Index to Programming Work SheetsProgramming Option Page[000] Keypad Enrollme

Page 23

Section 1: Installation & Wiring1Section 1: Installation & WiringThis Installation Guide provides the basic installation, wiring and programmi

Page 24

PowerSeries - PC1616/PC1832/PC1864285.2 Programming Worksheets Shaded programming sections indicate minimum programming requirementsSIA FAR CP-01 defa

Page 25

5.2 Programming Worksheets29[005] System Times For SIA CP-01 compliant installations, the Exit Delay must be within the range of 045-255 seconds (Defa

Page 26

PowerSeries - PC1616/PC1832/PC186430Programmable Output Options01 Residential Burglary and Fire Bell Output 18 Stay Armed Status 36 Zone Follower Ou

Page 27

5.2 Programming Worksheets31[013] First System Options[014] Second System Options[015] Third System Options[016] Fourth System OptionsOpt Def ON OFF1R

Page 28

PowerSeries - PC1616/PC1832/PC186432[017] Fifth System Options[018] Sixth System Options[019] Seventh System Options Keypad Zone Assignments[020] Keyp

Page 29 - Programming Option Page

5.2 Programming Worksheets33[021] Eighth System Options[022] Ninth System Options [023] Tenth System Options[030] Zone Loop Response (Zones 1-8)Opt De

Page 30 - 5.2 Programming Worksheets

PowerSeries - PC1616/PC1832/PC186434[101]-[164] Zone Attributes Zone Attribute Defaults (Y = Option ON; N = Option OFF): Bold entries are opposite for

Page 31 - [005] System Times

5.2 Programming Worksheets35Section Zone # Zone Audible/ Steady/ Chime Bypass Force* Swing Tx. Delay Wireless Cross ZnType** Silent Pulsed No No No N

Page 32 - Other System Options

PowerSeries - PC1616/PC1832/PC186436Section Zone # Zone Audible/ Steady/ Chime Bypass Force* Swing Tx. Delay Wireless Cross Zn Type** Silent Pulsed No

Page 33 - (ON for SIA CP-01)

5.2 Programming Worksheets37[167] T-LINK Interface Communications Wait for Acknowledge Default 020 I_______I_______I_______I Valid entries are 001-255

Page 34

PowerSeries - PC1616/PC1832/PC186421.1 Keybus WiringThe 4-wire KEYBUS (red, black, yellow and green) is the communication connection between the contr

Page 35 - 4][1], [4][2], [4][3]

PowerSeries - PC1616/PC1832/PC186438No Activity Arming Timers - Default is [000] for all partitionsSection Partition[191] 1 I_______I_______I_______I

Page 36 - [101]-[164] Zone Attributes

5.2 Programming Worksheets39Communications[304] Call Waiting Cancel String (6 Digits) - This feature is activated in Section 382 Opt 4I_______I_______

Page 37

PowerSeries - PC1616/PC1832/PC186440[324]-[327] Alarm Restoral Reporting Codes, Zones 01-64 Section[324] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zon

Page 38 - System Timers

5.2 Programming Worksheets41[334]-[337] Tamper Restoral Reporting Codes, Zones 01-64 Section[334] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Z

Page 39

PowerSeries - PC1616/PC1832/PC186442 [344] Miscellaneous Opening (Disarming) Reporting CodesI_______I_______IFor Future UseI_______I_______IFor Future

Page 40

5.2 Programming Worksheets43Call Direction Options[351]-[358] Alarm/Restore Communicator Call Directions [359]-[366] Tamper/Restore Communicator Call

Page 41

PowerSeries - PC1616/PC1832/PC186444[375] System Maintenance Communicator Call Directions [376] System Test Transmissions Communicator Call Directions

Page 42

5.2 Programming Worksheets45[381] Second Communicator Options[382] Third Communicator Options*This option must remain OFF for SIA CP-01 installations.

Page 43

PowerSeries - PC1616/PC1832/PC186446[402] DLS Downloading Telephone Number (32 Digits)|____D___|_______|_______|_______|_______|_______|_______|______

Page 44

5.2 Programming Worksheets47Section PGM Output 1 2 3 4 5

Page 45

Installation3PC1616/1832/1864 Wiring DiagramPC Boar d Cabinet Stand Of f Pr imar y:120V A C/60Hz. Secondar y: 16.5VAC 40VA DSCPTD 1640U Class II Tr

Page 46

PowerSeries - PC1616/PC1832/PC186448PGM Output Partition AssignmentSection PGM Partition: 1 2 3 4 5 6 7 8#Main Board[551] 1 I________I I________| I__

Page 47

5.2 Programming Worksheets49[605]-[608] Opening (Disarming) Reporting Codes, Access Codes 33-95Section [605] Code 33 Code 34 Code 35 Code 36 Code 37

Page 48 - Attribute: 12 3 4 5 678

PowerSeries - PC1616/PC1832/PC186450INTERNATIONAL PROGRAMMING[700] Automatic Clock Adjust Default = 60 |________|_________| Valid Entries 01-

Page 49

Module Programming51Module Programming[801] PC5400 Printer Module Programming Refer to the PC5400 Installation Manual for installation and programming

Page 50 - Extended Reporting Codes

PowerSeries - PC1616/PC1832/PC186452For the RecordCustomer: __________________________________________________________________________________________

Page 51

Module Programming53Zone Programming SummaryZone programming can be found in sections [001] - [004], [101] - [164], [020], [202]-[265]. Use this area

Page 52

PowerSeries - PC1616/PC1832/PC1864Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA format reporting codes. For mo

Page 53 - Module Programming

Appendix A: Reporting Codes[345]-[346] Auxiliary Power Trouble/Rest.Aux voltage supply trouble/restoral MA/R (3) 12 YP-00/YQ-00[345] TLM Failure Telep

Page 54 - For the Record

PowerSeries - PC1616/PC1832/PC1864Appendix B: UL Listed Commercial and Residential InstallationsThe installation requirements listed below must be met

Page 55 - Zone Programming Summary

Appendix C: SIA False Alarm ReductionAppendix C: SIA False Alarm ReductionSIA FeatureProgramming SectionComments Range/Default Require-mentExit Time[0

Page 56 - Appendix A: Reporting Codes

PowerSeries - PC1616/PC1832/PC186441.5 AUX Power WiringThe control panel can provide a maximum of 700mA of current for modules, powered detectors, rel

Page 57 - Appendix A: Reporting Codes

PowerSeries - PC1616/PC1832/PC1864Appendix D: Troubleshooting GuideTesting:• Power up system• Program options as required (See Programming Section)NO

Page 58 - SIA FAR Installations

Appendix D: Troubleshooting GuideTrouble Cause TroubleshootingTrouble [1] Service Required Press [1] to determine specific trou

Page 59 - Programming Section

PowerSeries - PC1616/PC1832/PC1864Trouble Cause TroubleshootingTrouble [2] AC FailureNo AC at panel AC input terminalsVerify voltage measured across A

Page 60 - Trouble Summary:

Appendix D: Troubleshooting GuideTrouble Cause TroubleshootingTrouble [5] Zone Fault (Cont.)One or more wireless devices have not checked in within th

Page 61 - Trouble Cause Troubleshooting

PowerSeries - PC1616/PC1832/PC1864Appendix E: Template ProgrammingTemplate programming allows quick programming of the minimum functions required for

Page 62

Appendix E: Template Programming• Digit 4 selects reporting code configurations Common Group Selected TroublesOptionCommonGroupSelectedTroublesOpening

Page 63

PowerSeries - PC1616/PC1832/PC1864Openings & ClosingsZone Restorals DLS/Installer Lead IN/OUTDigit 5 selects DLS connection options.Users CLOSINGS

Page 64

Note to InstallersThis warning contains vital information. As the only individual in contact with system users, it is yourresponsibility to bring each

Page 65 - Selected Troubles

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this eq

Page 66 - DLS/Installer Lead IN/OUT

Section 2: User Commands5Section 2: User CommandsAny system keypad can be used to program or perform any keypad command. LED keypads use status and zo

Page 67 - Note to Installers

PowerSeries - PC1616/PC1832/PC18646[][2] Trouble DisplayRefer to Appendix D – Trouble Conditions, for troubleshooting assistance and a detailed descr

Page 68 - INDUSTRY CANADA STATEMENT

Section 2: User Commands7[][6] – User FunctionsPress [][6] followed by the Master Code, then press the number corresponding to the following functio