DSC Envoy NT9010 Guide d'installation Page 59

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 58
Section 2.3: Changing Other NT9010 Functions
55
The system will take a few seconds to reset. When the keypad is operational, the
default is complete.
You can also return the main controller, wireless receiver and audio interface pro-
gramming to factory default settings individually. To return the main control to
default settings, use section [992]. To return the wireless receiver to default set-
tings, use section [996]. To return the voice prompt and audio interface program-
ming to default settings, use section [995].
NOTE:
If Installer Lockout is enabled [990], the relay will click 10 times
when individual defaults are performed (the section will still default).
NOTE:
It is recommended that an NT9010 default be performed when
any defaulting is required.
Restore NT9010 to default programming. . . . . . . . . . . . . . . . . . . . . . Section [999]
Restore main control only to default programming . . . . . . . . . . . . . . Section [992]
Restore wireless receiver only to default programming . . . . . . . . . . . . Section [996]
Restore voice prompt and audio interface only to
default programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [995]
Performing a Hardware Default of Main Controller
This procedure will return all NT9010 system programming to the factory default
settings, except for zone serial numbers, wireless receiver, and voice prompt inter-
face programming.
1. Remove the NT9010 unit from its backplate (see the Quick Set Up Guide for
instructions).
2. Remove all wires from the BLACK and GREEN terminals.
3. Disconnect the battery and wait 10 seconds.
4. With a piece of wire short the BLACK terminal to the GREEN terminal.
5. Return the NT9010 to the backplate until you hear a series of beeps from the unit.
6. Remove the NT9010 from the backplate again.
7. Reconnect all original wiring and the battery then return the NT9010 to the
backplate.
NOTE:
AC power must be used to power the system. The system will not
default if only the battery is used.
2.3.21 Installer
Lockout
If Installer Lockout is selected a hardware default cannot be performed.
When Installer Lockout Disable is selected the system will restore all program-
ming to factory defaults if a hardware or software default is performed.
To enable or disable Installer Lockout perform the following:
1. Enter Advanced Programming.
2. To enable Installer Lockout, enter section [990]. To disable Installer Lockout,
enter section [991].
3. Enter the Installer Code.
4. Enter section [990] or [991] again.
Vue de la page 58