1System IntroductionS E C T I O N 11.1 SpecificationsControl Panel SpecificationsFlexible Zone Configuration:• 8 Fully Programmable Zones• 38 Access
G E T T I N G S T A R T E D102.8 Removing ModulesIf a module is no longer required on the system the panel must be told to no longer supervise the mo
G E T T I N G S T A R T E D112.9.4 Fire Zone Wiring - 4 wire Smoke DetectorsAll zones defined as Fire (See Section 5.1 “Zone Definitions”) must be wi
G E T T I N G S T A R T E D122.10 Keypad ZonesKeypads with zone inputs can be connected to devices such as door contacts. This saves you fromrunning
Keypad CommandsS E C T I O N 313All keypads provide complete information and control of the alarm panel. The panel can be completely programmedvia an
K E Y P A D C O M M A N D S143.3 Auto BypassWhen the system is armed and any zone or zone(s) on the system have been programmed as Stay/Awaythe panel
K E Y P A D C O M M A N D S15A description of the various troubles are as follows:Trouble [1] - Service Required This light will be on if any of th
K E Y P A D C O M M A N D S16[✱]+[4] Door Chime On/OffIf enabled the keypad will beep 5 times rapidly when a zone is tripped and restored. The panel
K E Y P A D C O M M A N D S17How to erase Access Code:Select the code to be erased and press [✱].[✱]+[6] User FunctionsThis keypad command can be use
K E Y P A D C O M M A N D S18[✱✱✱✱✱] [7] Command Output FunctionsThere are four output functions available to the user. Each function can be performe
K E Y P A D C O M M A N D S19“Chime” - Door Chime On/OffPressing the key will toggle the Door Chime feature ON or OFF. One solid beep means the featu
S Y S T E M I N T R O D U C T I O N2False Alarm Prevention Features• Audible Exit Delay •Audible Exit Fault •Urgency on Entry Delay• Quick Exit •Swin
K E Y P A D C O M M A N D S20[14] - [✱]+[7]+[2] Smoke Detector ResetThis function key provides the user with a simple method for activating a PGM out
How to ProgramS E C T I O N 421The following section of the manual describes how to enter Installer Programming and how to program the varioussection
H O W T O P R O G R A M22If you are using a pulse format, a decimal zero [0] does not transmit. Programming a zero [0] tells thepanel not to send an
Program Descriptions23S E C T I O N 5The following section explains all the programmable features including how the feature operates, options thatper
P R O G R A M D E S C R I P T I O N S24[09] 24 Hour Supervisory Zone If this zone is violated, whether armed or disarmed, the panel will report toth
P R O G R A M D E S C R I P T I O N S25Swinger Shutdown Enable (Shall not be enabled on UL Listed systems) Determines if the panel willshut down th
P R O G R A M D E S C R I P T I O N S265.5 Communicator - Account NumbersThere are two Partition Identifier Codes (or Account Numbers) programmable,
P R O G R A M D E S C R I P T I O N S27If the SIA Sends Automatic Reporting Codes option is disabled the panel will operate as follows:1.If the repor
P R O G R A M D E S C R I P T I O N S28A Partial Closing Reporting Code will be transmitted if a Partition is armed with zones manuallybypassed. The
P R O G R A M D E S C R I P T I O N S29The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output isshorted. The A
S Y S T E M I N T R O D U C T I O N3WLS907 Wireless Slimline Universal TransmitterThe wireless Slimline Universal Transmitter can be used with the PC
P R O G R A M D E S C R I P T I O N S30Reporting Codes ... Sect
P R O G R A M D E S C R I P T I O N S31Keypads can be assigned to work on either partition or can be assigned for Global operation (SeeSection 2.6 “K
P R O G R A M D E S C R I P T I O N S32[10] Latched System Event (Strobe Output) The output will activate when any of the selected systemevents (al
P R O G R A M D E S C R I P T I O N S335.10.2 PGM Output AttributesIn addition to programming the output type, you must also program the PGM output a
P R O G R A M D E S C R I P T I O N S34Bell Cut-off ... Section [005]Bell Circuit Trouble
P R O G R A M D E S C R I P T I O N S35For commercial applications Bell Squawk on Entry Delay may be enabled. The panel will squawk thealarm output o
P R O G R A M D E S C R I P T I O N S365.19 Keypad BacklightingThe keys of all the keypads can be backlit to provide easy viewing in dim lighting con
P R O G R A M D E S C R I P T I O N S375.24 Loop ResponseThe normal loop response time for all zones is 500 milliseconds. The panel will not consider
P R O G R A M D E S C R I P T I O N S38Please refer to the LINKS1000 installation Manual for more information and connection diagrams.LINKS Preamble
P R O G R A M D E S C R I P T I O N S395.29 On-Site PrinterThe panel, with the addition of the PC5400 printer module, will print all events as they o
S Y S T E M I N T R O D U C T I O N4Three additional devices are available (These devices are not UL Listed):PC5921 Intercom Audio Station (This devi
P R O G R A M D E S C R I P T I O N S405.32 Installer LockoutIf Installer Lockout is selected a hardware default cannot be performed. If a software d
Contact IDThe Partition ID Codes must be 4 digits. All reporting codes must be 2 digits.The following is a list of Contact ID reporting codes. The fir
42SIA FormatLevel 2 (Hardcoded)The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communica-tion
LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc
© 1997 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Tel. (416) 665-8460 • Fax (416) 665-7498 • Tech. Line 1-80
PC5O1OVersion 2.ODLS-1 version 6.4 or laterWARNING This manual contains information on limitations regardingproduct use and function and information
FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use th
Table of ContentsiPC5010 Control Panel Hookup Diagram ... iiSection 1 - System Introduction1.1 Specifications ...
Hookup DiagramP C 5 0 1 0 C O N T R O L P A N E Lii
Getting StartedS E C T I O N 25The following sections provide a complete description of how to wire and configure devices and zones.2.1 Installation
G E T T I N G S T A R T E D62.2 Terminal DescriptionsAC Terminals - ACThe panel requires a 16.5 volt, 40 VA transformer. Connect the transformer to a
G E T T I N G S T A R T E D7Ensure the plugs and jacks meet the dimension, tolerance and metallic plating requirements of 47C.F.R. Part 68, SubPart F
G E T T I N G S T A R T E D8Other DevicesRead the manufacturer’s literature carefully to determine the maximum current requirement (duringactivation
G E T T I N G S T A R T E D92.6 Keypad AssignmentThere are 8 available slots for keypads. LED keypads by default are always assigned to slot 1 while