19
[01] Zone Definitions Page 13
NOTE: When defining zones, assign Delay Zones starting with Zone 1, then Zone 2, and so on.
Then, assign the other zone types to the remaining zones in any order desired.
Default
0 0 Zone 1
0 1 Zone 2
0 2 Zone 3
0 2 Zone 4
[02] System Times Page 14
Default
0 3 0 Entry Delay (seconds)
1 2 0 Exit Delay (seconds)
0 0 4 Bell Cut-off (minutes)
Valid entries are “001” to “255”; do not enter “000”.
[03] Installer’s Code Page 14
Default
0560
[04] Programmable Output Options (PGM Terminal) Page 14
Default
0 1 Programmable Output [01] [
][7] Utility Output Command activates PGM
[02] PGM follows Keypad Buzzer
[03] Arm/Disarm Status
[04] Remote Operation (through Downloading)
[05] First System Option Code Page 15
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 Momentary Keyswitch Maintained Keyswitch
ON Zone Light 2 [P] Key: silent alarm [P] Key: audible alarm
OFF Zone Light 3 KEY Terminal is tamper zone Keyswitch operation
OFF Zone Light 4 Police Code enabled Police Code disabled
PROGRAMMING WORKSHEETS
Digit 1 Digit 2
[0] Audible [0] Standard Delay
[1] Silent [1] Instant
[2] Interior
[3] Stay-Away with Delay
[4] 24-Hour Bell
[5] 24-Hour Pulsed Alarm
WWW.DIYALARMFORUM.COM
Vue de la page 18