DSC PowerSeries PC1864 Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Systèmes de contrôle d'accès de sécurité DSC PowerSeries PC1864. DSC PowerSeries PC1864 Installation guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
PowerSeries
PC1616/PC1832/PC1864 version 4.1
Installation Guide
Note to Installer:Center pages contain important end user information. Leave with End User.
WARNING: This manual contains information on limitations regarding product use and function and infor-
mation on the limitations as to liability the manufacturer. The entire manual should be carefully read.
Vue de la page 0
1 2 3 4 5 6 ... 63 64

Résumé du contenu

Page 1 - PowerSeries

PowerSeries PC1616/PC1832/PC1864 version 4.1Installation GuideNote to Installer:Center pages contain important end user information. Leave with End Us

Page 2 - Table of Contents

PowerSeries - PC1616/PC1832/PC18648Section 3: ProgrammingThis section provides the information necessary to program all required features for a basic

Page 3 - Installation

Section 3: Programming93.5 Viewing ProgrammingLED and LCD5501Z KeypadsLCD KeypadThe keypad will immediately display all the information programmed wh

Page 4 - Burglary Zone Wiring Chart

PowerSeries - PC1616/PC1832/PC186410Section 4 – Programming DescriptionsThe following is a brief description of the features and options available in

Page 5 - PC1616/1832/1864

Section 4 – Programming Descriptions11Section [005] System TimesAfter entering Section [005], enter the 2-digit subsection number for the desired part

Page 6 - DC - 14VDC

PowerSeries - PC1616/PC1832/PC186412Section [012] Keypad LockoutThe system can be programmed to ‘lockout’ keypads if a series of incorrect user or ins

Page 7 - Section 2: User Commands

Section 4 – Programming Descriptions13Section [014] Second System Option CodeSection [015] Third System Option CodeSection [016] Fourth System Option

Page 8

PowerSeries - PC1616/PC1832/PC186414Section [017] Fifth System Option CodeSection [018] Sixth System Option CodeSection [019] Seventh System Option Co

Page 9

Section 4 – Programming Descriptions15Section [020] Keypad Zone AssignmentEnter the two-digit zone number to be assigned to each keypad assigned to a

Page 10 - Section 3: Programming

PowerSeries - PC1616/PC1832/PC186416Section [165] Maximum Dialing AttemptsProgram the Maximum Dialing Attempts before the panel will generate a Failur

Page 11 - 3.6 DLS Programming

Section 4 – Programming Descriptions17Section [175] Auto-Arm Postpone TimerProgram the time, in minutes, that the system will postpone automatic armin

Page 12

Table of ContentsSection Description Page11.11.21.31.41.51.61.71.81.91.10Installation & Wiring...

Page 13

PowerSeries - PC1616/PC1832/PC186418Section [311] to [318] Partition Account NumbersProgram the Partition Account Number for each active partition (Se

Page 14

Section 4 – Programming Descriptions19Section [380] First Communicator Option CodeSection [381] Second Communicator Option CodeSection [382] Third Com

Page 15 - ][5] command

PowerSeries - PC1616/PC1832/PC186420Section [401] First Downloading Option CodeSection [402] Downloading Computer Phone NumberThe Downloading Computer

Page 16

Section 4 – Programming Descriptions21PGM Output Option [01], [03] to [08], [11] to [22], [25]PGM Output Option [19] to [22]PGM Output Option [09]PGM

Page 17

PowerSeries - PC1616/PC1832/PC186422Section [701] First International Option CodeSection [702] Second International Option CodeSection [703] Delay Bet

Page 18

Section 4 – Programming Descriptions23Section [900] Special Installer InstructionsSection [900]: Display Panel VersionOnly available with LCD5500 or P

Page 19 - ] key press

PowerSeries - PC1616/PC1832/PC186424Section [993] to [999]: Factory Default Module/PanelThe following Sections can be used to factory default a module

Page 20

Section 5: Programming Work Sheets25Section 5: Programming Work Sheets5.1 Index to Programming Work SheetsProgramming Option Page[000] Keypad Enrollme

Page 21 - Option Description

PowerSeries - PC1616/PC1832/PC1864265.2 Programming Worksheets Shaded programming sections indicate minimum programming trerquirementsSIA FAR CP-01 de

Page 22

5.2 Programming Worksheets27[005] System Times For SIA CP-01 compliant installations, the Exit Delay must be within the range of 045-255 seconds (Defa

Page 23

Section 1: Installation & Wiring1Section 1: Installation & WiringThis Installation Guide provides the basic installation, wiring and programmi

Page 24

PowerSeries - PC1616/PC1832/PC186428Programmable Output Options01 Residential Burglary and Fire Bell Output 15 Remote Operation (DLS-3 Support)02 For

Page 25

DSC PowerSeries Alarm System User GuideAbout Your Security SystemYour DSC Security System has been designed to provide you with the greatest possi-ble

Page 26

Download complete User manual from www.dsc.comEmergency KeysPress the (F), (A) or (P) key for 2 seconds to generate a Fire, Auxiliary orPanic ala

Page 27 - Programming Option Page

DSC PowerSeries Alarm System User Guide6-digit user code or press [4] to delete the user code. After the user code is pro-grammed or deleted, enter a

Page 28 - 5.2 Programming Worksheets

Download complete User manual from www.dsc.com’Split level arrangement: Smoke detectors are required where shown. Smoke detec-tors are optional where

Page 29 - [005] System Times

5.2 Programming Worksheets29[013] First System Options[014] Second System Options[015] Third System Options[016] Fourth System OptionsOpt Def ON OFF1R

Page 30 - Other System Options

PowerSeries - PC1616/PC1832/PC186430[017] Fifth System Options[018] Sixth System Options[019] Seventh System Options - For Future UseKeypad Zone Assig

Page 31 - PK5500 Language Selection

5.2 Programming Worksheets31[023] Tenth System Options[030] Zone Loop Response (Zones 1-8)Opt Def ON OFF1RFire Key Beeps Only9RFire Key Beeps and Soun

Page 32 - [4] Commands

PowerSeries - PC1616/PC1832/PC186432[101]-[164] Zone Attributes Zone Attribute Defaults (Y = Option ON; N = Option OFF): Bold entries are opposite for

Page 33

5.2 Programming Worksheets33 Section Zone # Zone Audible/ Steady/ Chime Bypass Force* Swing Tx. Delay Wireless Cross ZnType** Silent Pulsed No No No N

Page 34 - New Zealand Telecom Network

PowerSeries - PC1616/PC1832/PC186421.1 Keybus WiringThe 4-wire KEYBUS (red, black, yellow and green) is the communication connection between the contr

Page 35 - (ON for SIA CP-01)

PowerSeries - PC1616/PC1832/PC186434System Timers[165] Maximum Dialing Attempts to Each Telephone Number Default 005 I_______I_______I_______I Valid e

Page 36

5.2 Programming Worksheets35No Activity Arming Timers - Default is [000] for all partitionsSection Partition[191] 1 I_______I_______I_______I Valid e

Page 37 - [023] Tenth System Options

PowerSeries - PC1616/PC1832/PC186436Communications[304] Call Waiting Cancel String (6 Digits) - This feature is activated in Section 382 Opt 4I_______

Page 38 - [101]-[164] Zone Attributes

5.2 Programming Worksheets37[324]-[327] Alarm Restoral Reporting Codes, Zones 01-64 Section[324] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Zo

Page 39

PowerSeries - PC1616/PC1832/PC186438[334]-[337] Tamper Restoral Reporting Codes, Zones 01-64 Section[334] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zo

Page 40

5.2 Programming Worksheets39 [350] Communicator Format Options Default04I_______I_______I 1st Telephone Number04I_______I_______I 2nd Telephone Numbe

Page 41

PowerSeries - PC1616/PC1832/PC186440Call Direction Options[351]-[358] Alarm/Restore Communicator Call Directions [359]-[366] Tamper/Restore Communicat

Page 42

5.2 Programming Worksheets41[377] Communication VariablesDefault 003 I___0__I__0__I___1__I Swinger Shutdown (Alarms and Rest) 001-014 Transmissions003

Page 43

PowerSeries - PC1616/PC1832/PC186442[382] Third Communicator Options*This option must remain OFF for SIA-FAR installations.** A Call Waiting Cancel on

Page 44

5.2 Programming Worksheets43[501]- [554]Programmable Output Attributes Program only the following attributes for the PGM options listed. All others wi

Page 45 - 2nd Telephone Number

Installation3PC1616/1832/1864 Wiring DiagramPC BoardCabinetStand OffPrimary:120VAC/60Hz.Secondary: 16.5VDC 40VADSCPTD 1640UClass II TransformerNOTE: D

Page 46

PowerSeries - PC1616/PC1832/PC186444Section PGM Output 1 2 3 4 5 6 7 8#Type*Main Board[501] 1 ( )I________I I________| I________| I________|

Page 47

5.2 Programming Worksheets45INTERNATIONAL PROGRAMMING[700] Automatic Clock Adjust Default = 60 |________|_________| Valid Entries 00-99 Secon

Page 48

PowerSeries - PC1616/PC1832/PC186446Special Installer Functions[900] Panel Version Displayed[901] InstallerWalk Test Mode Enable/Disable [902] Module

Page 49

Appendix A: Reporting CodesAppendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA format reporting codes. For more info

Page 50

PowerSeries - PC1616/PC1832/PC1864[345]-[346] Auxiliary Power Trouble/Rest.Aux voltage supply trouble/restoral MA/R (3) 12 YP-00/YQ-00[345] TLM Failur

Page 51

Appendix B: UL Listed Commercial and Residential InstallationsAppendix B: UL Listed Commercial and Residential InstallationsThe installation requireme

Page 52

PowerSeries - PC1616/PC1832/PC1864Appendix C: SIA False Alarm ReductionSIA FeatureProgramming SectionComments Range/Default Require-mentExit Time[005]

Page 53 - Appendix A: Reporting Codes

Appendix D: Troubleshooting GuideAppendix D: Troubleshooting GuideTesting:• Power up system• Program options as required (See Programming Section)NOT

Page 54 - Rep Codes**

PowerSeries - PC1616/PC1832/PC1864Trouble Cause TroubleshootingTrouble [1] Service Required Press [1] to determine specific tro

Page 55 - SIA FAR Installations

Appendix D: Troubleshooting GuideTrouble Cause TroubleshootingTrouble [2] AC FailureNo AC at panel AC input terminalsVerify voltage measured across AC

Page 56 - Programming Section

PowerSeries - PC1616/PC1832/PC186441.5 AUX Power WiringThe control panel can provide a maximum of 700mA of current for modules, powered detectors, rel

Page 57 - Trouble Summary:

PowerSeries - PC1616/PC1832/PC1864Trouble Cause TroubleshootingTrouble [5] Zone Fault (Cont.)One or more wireless devices have not checked in within t

Page 59

NOTES

Page 60

Note to InstallersThis warning contains vital information. As the only individual in contact with system users, it is yourresponsibility to bring each

Page 61

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this eq

Page 62

Section 2: User Commands5Section 2: User CommandsAny system keypad can be used to program or perform any keypad command. LED keypads use status and z

Page 63 - Note to Installers

PowerSeries - PC1616/PC1832/PC18646[4][2] Trouble DisplayRefer to Appendix D – Trouble Conditions, for troubleshooting assistance and a detailed descr

Page 64

Section 2: User Commands7[4][6] – User FunctionsPress [4][6] followed by the Master Code, then press the number corresponding to the following functio

Commentaires sur ces manuels