Power 864SECURITY SYSTEM®TMProgrammingWorksheetsDLS-3 v1.3 and higherPC5O2O/PC5O2OCF Version 3.2Now classified in accordance with ANSI/SIA CP-01-2000
8[016] Fourth System Option CodeDefault Option ON OFFONI________I 1 AC Trouble Displayed AC Trouble Not DisplayedOFFI________I 2 Trouble Light Fla
9Section 4: Advanced System ProgrammingZone Attributes Zone Attribute Defaults (Y = Option ON; N = Option OFF):Section Zone # Zone Audible/ Steady/ Ch
10Section Zone # Zone Audible/ Steady/ Chime Bypass Force Swing Tx. Delay Wireless Cross ZnType** Silent Pulsed No No No No No No No12345 6789[115]
Advanced System Programming11System Timers[165] Maximum Dialing Attempts to Each Telephone Number Default: 007I_______I_______I_______I Valid entries
12[190] No Activity Arming Pre-Alert Time Default Partition Default 001 All I_______I_______I_______I Valid entries are 001-255 seconds, 000 for n
13Section 5: Partition and Zone Programming[201] Partition Selection Mask Select which partitions will be active on the systemNOTE: Partition 1 canno
14Assigning Zones to Partitions (cont.)Section Partition Zone:Section Partition Zone:[218] 3 01 02 03 04 05 06 07 08I________I I________I I________I I
Partition and Zone Programming:15Assigning Zones to Partitions (cont.)Section Partition Zone:[242]6 0102030405060708I________I I________I I________I I
16Section 6: Communicator ProgrammingTelephone NumbersNOTE: For sections [301] to [353], the content of every section by default is [F].[301] First T
Communicator Programming17Alarm Restoral Reporting Codes, Zones 01-64 Section[324] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Zone 07 Zone 08
Table of ContentsPower864 Programming Guidelines Inside Back CoverSection 1: For the Record 1Account Information ...
18Tamper Restoral Reporting Codes, Zones 01-64 Section[334] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Zone 07 Zone 08 I_______I_______I I____
Communicator Programming19[344] Miscellaneous Opening (Disarming) Reporting Codes I_______I_______I Opening by Duress Code 33I_______I_______I Opening
20[349] PC5700 Maintenance Reporting Codes I_______I_______I PC5700 Ground Fault TroubleI_______I_______I PC5700 Ground Fault RestoreI_______I_______I
Communicator Programming:21Opening/Closing Communicator Call Directions NOTE: The LINKS1000 backup call directions will only back up their respective
22Communicator Options[380] First Communicator Option Code Default Option ON OFF ONI_______I 1 Communications Enabled Communications DisabledOFFI
23Section 7: Downloading Options[401] First Downloading Option Code Default Option ON OFFOFF I_______I 1 Answering machine/double call enabled An
24Section 8: Programmable Output ProgrammingProgrammable Output Attributes Program only the following attributes for the PGM options listed. All other
25Section PGM Output 1 2 3 4 5 6 7 8#Type*Main Board[501] 1 ( )I________I I________| I________| I________| I________| I________| I________|
26Section 9: International Programming[700] Clock AdjustDefault: 60 I_______I______I Valid entries are 01-99 seconds[701] First International Options
27Section 10: Module Programming[801] PC5400 Printer Module Programming Please refer to your PC5400 Installation Manual for installation and programmi
1Section 1: For the RecordAccount InformationCustomer:________________________________________________________________________________________________
28Section 11: Special Installer Functions[901] Installer Walk Test Mode Enable / Disable [902] Module Supervision Reset [903] Module Supervision Fiel
29Appendix A: Programming LCD5500Z KeypadsIf you have an LCD5500Z keypad, additional programming is required for proper operation. All LCD programming
30[60] First User Display MaskDefault Option ON OFFONI_______I 1 Hold [P]anic Keys prompt ON Hold [P]anic Keys prompt OFFONI_______I 2 Zone Bypassing
31[66] Keypad OptionsDefault Option ON OFFONI_______I 1 Display Access Code when Programming Display ‘X’ when ProgrammingONI_______I 2 Local Clo
32Programmable Labels Zone labels and other LCD display identifiers can be customized to make operation of the system easier for the end user. The fol
33[075] Fourth User Display MaskDefault Option ON OFFON I_______I 1 User Initiated Call-up prompt ON User Initiated Call-up prompt OFFOFFI_______I
34Command Output LabelsDefault: “Command_O/P_1” - “Command_O/P_4”Program a label for each Command Output used, as it will appear at each partition ( o
35[997] View Software Version[998] Initiate Global Label BroadcastAll LCD programming is done per keypad. If more than one LCD keypad are present on t
36Appendix B: Programming LCD5501Z KeypadsThere are several programming options available for the LCD5501Z keypad. These are described below. Record a
37Programming Door Chime OptionsYou can program the LCD5501Z keypad to sound a tone when any zone is opened or closed. There are two parts to the LCD5
2Zone Programming SummaryZone programming can be found in sections [001] - [004], [101] - [164], [020] and [202] - [265]. Use this area to record a s
38Zone Location Options: [1] [2] [3] [4]3 Beeps “Bing-bing” “Ding-dong” Alarm tone(default)[26]I____________________________________________________
39Appendix C: PC5020 Commercial Fire Programming Guide This section is to be used for programming features related directly to Central and Remote Stat
40[350] Communicator Format OptionsDefault: 04 SIA FSK I________I________I SIA -FSK is the approved format for Commercial Fire Applications.NOTE
Power864 Programming GuidelinesItem Page Section Item Page SectionZone Programming PagerZone Definitions 20 [001]-[004] First, Second, Third Phone Num
©2001 Digital Security Controls Ltd.Toronto • Canada • 1-800-387-3630 • www.dsc.comPrinted in Canada 29005908 R002FCC Compliance StatementCAUTION: Ch
For the Record3*Zone Attributes:Option 1: Audible/Silent Option 5: Force ArmingOption 2: Steady/Pulsed Option 6: Swinger ShutdownOption 3: Chime Opti
4Section 2: Keypad Programming[000] Keypad Enrollment NOTE: This must be done at each keypad requiring programming.[0] Slot address [Valid entries
5Section 3: Basic ProgrammingZone DefinitionsNOTE: To use 24-hour Buzzer zones, keypads must be installed .NOTE: Keypad zones are assigned in section
6System Times and Codes[005] System Times[006] Installer’s Code Default5555I_______I_______I_______I_______I[007] Master Code Default1234I_______I____
Basic Programming7[011] PGM11 to PGM14 Output Programming (PC5204) NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partiti