DSC PowerSeries PC1864 Guide d'installation Page 60

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 59
PowerSeries - PC1616/PC1832/PC1864
Trouble Cause Troubleshooting
Trouble [5] Zone Fault (Cont.)
One or more wireless devices have not
checked in within the programmed time
If the trouble occurs immediately, a conflict with a hard wired
zone exists:
The zone being used is already assigned to a PC5108 zone
expander
The zone being used is assigned as a keypad zone
Perform a Module Placement Test – Program Section [904] and
verify the wireless device is in a good location.
If bad test results occur, test the wireless device in another
location
If the wireless device now tests good, the original mounting
location is bad
If the wireless device continues to give bad test results
replace the wireless device
A short circuit is present on one or more
zones with double end-of-line resistors
enabled
Remove the wire leads from Z and COM terminals and measure
the resistance of the wire leads.
A short circuit indicates a short in the wiring.
Connect a 5.6K resistor (Green, Blue, Red) across the Z and
COM terminals.
Verify the trouble condition clears.
Trouble [6] Zone Tamper Press [6] to determine specific zones with a tamper trouble
A tamper condition is present on one or
more wireless devices
Perform a Module Placement Test –Section [904]
Violate, then restore the tamper:
If no test result then replace wireless device
An open circuit is present on one or more
zones with double end-of-line resistors
enabled
Remove the wire leads from Z and COM terminals.
Measure the resistance of the wire leads.
Open circuit indicates a break in the wiring.
Connect a 5.6K resistor (Green, Blue, Red) across the Z and
COM terminals.
Verify the trouble condition clears.
Trouble [7] Wireless Device Low Battery Press [7] to toggle through specific devices with low battery trouble
1st press
– Wireless Zones
2nd press
– Handheld Keypads
3rd press
– Wireless Keys
One or more wireless devices has a low
battery
NOTE: The event will not be logged to
the event buffer until the wireless device
low battery delay time expires
Program Section [377] Opt 9
Replace battery
NOTE: Replacing batteries will cause a tamper. Replacing cover will
restore the tamper causing the associated reporting codes to be sent
to the Central Station.
Trouble [8] Loss of Clock/Date
The main panel internal clock is not set To program the time and date:
Enter [][6][Master Code] then Press [1]
Enter the time and date (in military) using the following format:
HH:MM MM/DD/YY
Example.
For 6:00 pm, June 29, 2005
Enter: [18] [00] [06] [29] [05]
IMPORTANT!
Ensure you have the following information available before contacting Customer Support
- Control Panel Type and Version, (e.g., PC1864 v4.1)
NOTE: Version number can be accessed by entering [
][Installer Code][900] on any LCD keypad. This informa-
tion is also located on a sticker on the Printed Circuit Board.
- List of modules connected to Control Panel, (e.g., PC5400, PC5204 etc.)
Vue de la page 59
1 2 ... 55 56 57 58 59 60 61 62 63 64

Commentaires sur ces manuels

Pas de commentaire