46
Module Programming
[804]-[82-85] Zone Transmitter Supervision
Options
These eight bit toggle sections determine which wireless zones on
the system are supervised. All zones that are enabled will be super-
vised for communication integrity, and will operate according to the
zone type programmed.
If a zone is disabled, it will not be supervised and zone
activity will be ignored by the panel. See section [202-
205].
Sub-
Section
Zone Enabled Disabled
[82] 01
!
02
!
03
!
04
!
05
!
06
!
07
!
08
!
[83] 09
!
10
!
11
!
12
!
13
!
14
!
15
!
16
!
[84] 17
!
18
!
19
!
20
!
21
!
22
!
23
!
24
!
[85] 25
!
26
!
27
!
28
!
29
!
30
!
31
!
32
!
[901] Installer Walk Test Enable/
Disable
[*]
Function
When this mode is ON, all zones become 24-Hr non force-armable
zones that will sound the bell (steady or pulsed ) for 2 seconds and
transmit their programmed alarm reporting codes (section [320-
323]) when violated. If the user attempts to arm while in Walk Test
the keypad will sound an error.
Fire Troubles are not supported in Walk Test.
Alarm Memory is cleared upon entering Walk Test.
To Enable Walk Test Mode:
Disable ‘Keypad Blanking’ - section [016] option 3
Disable ‘Fire Bell is Continuous’ - section[016] option 8
Enter from normal state:
[*] [8] [Install Code] [2] [901]
To Disable Walk Test Mode:
Re-enter:[*] [8] [Install Code] [2] [901]
Re-enable ‘Keypad Blanking’ and ‘Fire Bell Continuous’ if
required.
The User Walk Test ([*][6][8]) performs the same functions
as indicated here except that reporting codes are not trans-
mitted to the central station.
[902] Reset Module Supervision
All modules will automatically enroll within one minute upon
power-up. If modules are removed, enter this section to clear
any supervisory troubles that may be present. When this mode
is entered the system will attempt to re-enroll all modules.
When this section is entered, all pending Supervisory Trouble
Restorals will not be logged or transmitted.
If a module is NOT communicating properly with the system,
it will be deleted when you enter this section.
To Reset Module Supervision:
Enter from normal state:
[*] [8] [Install Code] [2] [902]
[903] Module Supervision Field
When this section is entered, the system will display all mod-
ules enrolled on the system.
[*] [8] [Install Code] [2] [903]
[904] Device Placement Test
FLASH
Device Selection - When this section is entered, a two digit entry is
required to select the zone number to be tested (01-32). If a device
is selected that is not enrolled, an error tone will sound.
Placement Indication - After the zone is selected the device sends
a signal to the NT9005 to register a signal strength value. These
results are indicated in the following table.
Indication LCD Bell/Buzzer
Good
Bad
Not Enrolled
Good
Bad
-
1 Beep/Squawk
3 Beep/Squawk
Error Tone
7
Chapter 2: Installation
2-1 Installation Procedure
Read the following procedure to familiarize yourself
with the necessary steps before installing the system.
1. Create a Layout - Draw a rough sketch of the
building and include all alarm detection devices,
modules and PGM output devices. Refer to the
following paragraphs for wiring requirements.
Keybus, Para 2-3.1
PGMs Para 2-3.2
Hardwired Zones Para 2-3.3
Telephone Line Wiring. Para 2-3.4
Battery and AC Wiring. Para 2-3.5
Refer to paragraph 2-4 and the associated instal-
lation sheets for placement of wireless detectors.
Locate the control panel in a dry area, near an
unswitched AC source and telephone line. Avoid
areas that are a possible source of electrical noise
such as computers, televisions, appliances, HVAC
systems. Avoid areas with large metal surfaces
such as heating ducts.
Ensure that the control panel and other mod-
ules will be installed in an area that will be
protected by the system.
2. Mount Modules - Mount NT9204, Skyroute
modules as indicated in the associated installa-
tion manuals. Mount hardwired and PGM output
devices as required.
3. Route Wiring - Route the telephone line, AC
power line, PGM wiring, hardwired zone wiring
or Keybus wiring to the NT9005 panel location.
4. Install NT9005 Back Cover- Route wiring
through the access holes provided and mount the
back cover. Refer to paragraph 2.2 ‘NT9005
Installation’.
5. Complete Wiring - Connect the telephone line,
AC power line, PGM wiring, hardwired zone wir-
ing or Keybus wiring to the back cover.
6. Power up Control Panel - Connect the backup
battery. Place the unit on mounting plate ensur-
ing that the header on the printed circuit board
aligns with the terminal block on the back plate.
The system will NOT power up if only the
battery is connected.
Ensure that the LCD display and buzzer are func-
tioning as described during the power up
sequence. See Start-up, paragragh 1-5.1.
7. Position and Enroll Wireless Detectors. This
can be performed in Flash Programming or sec-
tion [904] in Advanced Programming (placement
only). Refer to the Installation Sheets of wireless
devices to determine optimal placement. Mount
wireless devices after succesful placement. Refer
to appendices C, D and E
8. Program the System. The system can be quickly
programmed for basic setup in Flash Program-
ming or custom programmed manually in
Advanced Programming or with DLS-3 (down-
loading software) using a remote or local com-
puter. See Chap. 3: Programming.
9. Test the System. Two system tests are available:
the user Walk Test available in [*][6][8] program-
ming or the installer Walk Test described in sec-
tion [901] in Advanced Programming.
In the User Walk Test report codes are not
sent to the central station.
2-2 NT9005 Installation
The NT9005 back cover comes attached to the back
of the NT9005 control unit. The back cover acts as a
mounting plate for the unit.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM