30
[017] Fifth System Option Codes
1 ON WLS Key does not use Access Code
!
The panel will NOT accept the disarm keycode from an uni-
dentified wireless key. An access code must be used with a
wireless key for proper operation.
OFF WLS Key uses Access Code
The panel will accept the disarm keycode from an unidenti-
fied wireless key, allowing arming/disarming without a code.
☞
Access codes for keys 1-16 are programmed in *Star 5 Func-
tions ([*][5][17]-[32]).
2 ON Auto-arm Schedule in [*][6]
!
This enables the user to access auto-arming by day in the
[*][6] menu. When ON, the user may select the day by press-
ing 1 to 7 for Sunday to Saturday.
OFF Auto-arm Schedule in Installer Program-
ming Only
The user can not access auto arming in the [*][6] menu.
3Future Use
4 ON Double Hit Enabled
When this option is enabled, two alarms from the same zone
will cause the Burglary Verified Police Code to be logged and
transmitted. This feature only applies to zones defined as
Interior, Interior Delay, Interior Stay/Away, or Delay Stay/Away
(PIR zones). This is an extension of the existing Police Code
☞
This feature is directly affected by the Burglary Verified Timer.
OFF Double Hit Disabled
!
5 ON Late to Close Enabled
This determines if the Late to Close reporting code is sent at
the end of the Auto-arm/Postpone pre-alert. If the auto-arm
toggle option is disabled, the Auto-arm pre-alert must still
occur if there is a time programmed for that day if this option
is enabled. This option does not directly affect the operation
of auto-arm.
This feature is used in installations that require an audible
warning if the panel is not armed by a certain time of day,
Anyone who hears this warning should in turn manually arm,
or contact the central station to let them know why the panel
has not been armed by the programmed time.
OFF Late to Close Disabled
!
6 ON Daylight Savings Time Enabled
OFF Daylight Savings Time Disabled
!
7Future Use
8 ON Arm/Disarm Squawk only on Away Arm
!
If section [014] option [1] is enabled, the bell will squawk dur-
ing Away arming and when disarming from Away mode.
OFF Arm/Disarm Squawk on all Arming types
If section [014] option [1] is enabled, the bell will always
squawk when arming and disarming.
[018] Sixth System Option Codes
1 ON Keybus Enabled
Keybus Expansion Enabled. The two flexible ports are set to
run external Keybus for module support.
OFF PGM/Zones Enabled
!
2 ON RF Jam Logs after 5 minutes
!
An RF Jam trouble will be indicated in [*][2][1] icon 6 after 30
seconds, but will log and transmit a General System Trouble
[*][2][1] icon 3 after a 5 minute delay.
OFF RF Jam Logs after 15 Seconds
RF Jam will Log/Transmit and indicate in [*][2][1] icon 6 after
15 seconds.
3 ON Tampers Sound Buzzer while Disarmed
When a tamper occurs on the system, and the system is in a
disarmed state, the buzzer will latch on until a valid access
code is entered.
OFF Tampers Do NOT sound Buzzer
!
4 ON Audible Exit with Urgency (Stay)
The keypad will sound a pulsing tone (once per second) dur-
ing the Exit Delay. For the last 10 seconds of the Exit Delay,
the keypad and bell/siren (if enabled) will sound a different
tone (3 tones per second).
OFF Silent Exit Delay (Stay)
!
5 ON Wireless Key Disarm During Entry Only
Entry delay must be active for wireless key disarm to work.
OFF Wireless Key Disarm Always
!
6 ON RF Jam Trouble Beeps after 15 seconds
General system trouble from RF jam detection is audible.
OFF RF Jam Trouble Silent
!
General system trouble from RF jam detection is silent
7 Future Use
8 ON RF Jam Trouble Disabled
!
The system will ignore RF interference.
OFF RF Jam Trouble Enabled
The system will monitor for RF noise or signals that will block
wireless transmissions to the unit.
[019] Seventh System Option Codes
1 Future Use
2 ON Communications During Walk Test
Zone Alarms/Tampers/Restores will communicate during
Installer’s Walk Test
OFF NO Communications During Walk Test
!
Zone Alarms/Tampers/Restores will NOT communicate during
Installer’s Walk Test
3-8 Future Use
23
[000][7] Keypad Priority Key Options
1 ON [F] Key Enable !
Holding the [F] Key is two seconds generates a fire alarm.
OFF [F] Key Disable
2 ON [A] Key Enable !
If the [A] Key is held for two seconds an auxiliary alarm is
generated.
OFF [A] Key Disable
3 ON [P] Key Enable !
If the [P] Key is held for two seconds a panic alarm is
generated.
OFF [P] Key Disable
4 ON Leading ‘0’ on Clock Displayed
OFF Leading ‘0’ on Clock Not Displayed !
5-8 Future Use
[001]-[004] Zone Definition
Op Description
00 Null - This zone will not operate in any way. For zones
not used and not requiring a closed loop or EOL resis-
tor. Typically used for zones that are not used.
01 Delay 1 - If this zone is violated when the system is
armed, it will provide an entry delay. The keypad
buzzer will sound to warn the user that the system
must be disarmed. If the system is not disarmed
before the entry delay expires, an alarm will be gener-
ated. Typically this type of zone will be used for the
front door or any other entry/exit point. Refer to sec-
tion [005] , ‘System Times’, to program this delay.
02 Delay 2 - This zone operates the same as Delay 1 but
provides a different entry delay. Typically this zone will
be used for a garage door. Refer to section [005] ,
‘System Times’, to program this entry delay.
03 Instant - If this zone is violated when armed, it will
cause an instant alarm. Typically this zone is used for
windows and other perimeter type zones.
04 Interior - If this type of zone is violated when the sys-
tem is armed it will follow entry delay if a delay type
zone was violated first. Otherwise it will cause an
instant alarm. Typically this zone type is used for inte-
rior protection devices such as motion detectors.
05 Interior Stay/Away - This zone works the same as the
Interior zone type except that the zone will be bypassed
under the following conditions:
- the system is armed in Stay mode.
- the system is armed without entry delay.
- the system is armed with an access code and during the
exit delay, a Delay zone is NOT tripped.
The automatic bypass avoids having the user manually
bypass interior type zones when arming at home. If auto-
matically bypassed, the user can reactivate the zones by
entering the [*][1] command (see [*][1] Zone Bypass-
ing. Typically this zone type is used for interior protection
devices such as motion detectors.
06 Delay Stay/Away This zone will operate the same as
the Interior Stay/Away zone except that it will always
provide entry delay. Typically this zone is used for interior
protection devices such as motion detectors and will help
prevent false alarms since it will always provide the user
with the entry delay time to turn off the system.
07-09 Future Use
10
☞
24-Hr Supervisory Buzzer - This zone is active at all
times and will report an alarm at all times. When tripped
the keypad buzzer will sound until a valid access code is
entered.
Do NOT use on a keyswitch only system.
11 24-Hr Burglary - This zone is active at all times and will
report an alarm if armed or disarmed. This zone will
sound the bell for the length of Bell Cutoff if the audible
attribute is enabled.
12
☞
24-Hr Holdup - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
This zone gives a silent alarm by default
13 24-Hr Gas - Similar to 24-Hr Burglary except for System
Event output type and SIA identifier.
14 24-Hr Heat - Similar to 24-Hr Burglary except for System
Event output type and SIA identifier.
15 24-Hr Medical - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
16 24-Hr Panic - Similar to 24-Hr Burglary except for System
Event output type and SIA identifier.
17 24-Hr Emergency. - Similar to 24-Hr Burglary except for
System Event output type and SIA identifier.
18 24-Hr Sprinkler - Similar to 24-Hr Burglary except for
System Event output type and SIA identifier.
19 24-Hr Water - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.