Installation Manual
PC5010 CP-01
IMPORTANT
This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
PC5010 CP-01 Version 3.2
DLS2002 and higher
Now classified in accordance with ANSI/SIA CP-01-2000 (SIA-FAR)
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - Installation Manual

Installation ManualPC5010 CP-01IMPORTANTThis manual contains information on limitations regarding product use and function and information on the limi

Page 2

4BackplatesThere are two different backplates available for keypadsto mount an audio station next to a keypad:PC55BP1 BackplateUse this backplate when

Page 3 - New Features

5Section 2: Installation and WiringThe following sections provide a complete description of how to wire and configure devices and zones.2.1 Installati

Page 4 - Description

6Keybus Terminals - RED, BLK, YEL, GRNThe Keybus is used by the panel to communicate withmodules and by modules to communicate with the panel.Each mod

Page 5 - Table of Contents

Installation and Wiring: 2.6 Assigning Zones to Zone Expanders7PC5010 CP-01 Device Ratings (@ 12 VDC)• LCD5500Z/LCD5520Z Keypad: 85 mA• LCD5501Z Keypa

Page 6 - PC5010 CP-01 Wiring Diagram

8How to Program Function KeysEach of the 5 function keys on each keypad may be pro-grammed for different operation.1. Enter Installer Programming. 2.

Page 7 - Section 1: Introduction

Installation and Wiring: 2.10 Zone Wiring9End of Line Resistors . . . . . . . . . . . . . . . . Section [013], Option [1]Single End of Line Resistors

Page 8 - 1.4 Additional Devices

10LINKS 2X50/LINKS 3000/Skyroute™Refer to the LINKSX50, LINKS3000 and Skyroute™Installation Manuals for wiring and installation details.2.11 Keypad Zo

Page 9 - Introduction:

11Section 3: How to ProgramThe following section of the manual describes how toenter Installer Programming and how to program the var-ious sections.NO

Page 10 - PC55BP2 Backplate

123.5 Viewing ProgrammingLED and LCD5501Z KeypadsAny programming section can be viewed from an LED orLCD5501Z keypad. When a programming section isent

Page 11 - 2.2 Terminal Descriptions

13Section 4: Keypad CommandsUse any system keypad to enter commands, or to program the PC5010 CP-01 security system. The LED keypad uses functionand z

Page 13 - 2.7 Keypad Assignment

14The keypad will display the event number, partition, timeand date of the event in question. Use the [*] key to togglebetween this information and th

Page 14 - 2.10 Zone Wiring

Keypad Commands: 4.2 [*] Commands15[*] [3] Alarm MemoryThe memory light will be on if any alarm occurred duringthe last armed period or if an alarm oc

Page 15 - Loop Resistance Loop Status

16Installer Programming - Codes and OptionsThere are three codes which can be programmed by theinstaller in Installer Programming: the Master CodeMast

Page 16 - 2.11 Keypad Zones

Keypad Commands: 4.3 Function Keys17[*] [0] Quick ArmIf the Quick Arm EnableQuick Arm EnableQuick Arm EnableQuick Arm Enable option is enabled the pan

Page 17 - Section 3: How to Program

18[15] - General Voice Prompt HelpThis feature can only be programmed if both theEscort5580(TC) and the PC5936 audio matrix module arebeing used. When

Page 18 - 3.5 Viewing Programming

19Section 5: Programming SectionsThe structure of this section corresponds with the structure of the Programming Worksheets (PWS) and is intended to b

Page 19 - Section 4: Keypad Commands

205.1 For the Record PWS Sect 1This Section identifies the client, installation date, Installer Code, hardware configuration and programming summary f

Page 20 - ] Commands

Programming Sections: 5.3 Basic Programming PWS Sect 321[005] - System TimesThis section has 3 sub-sections, 1 for each of the 2 parti-tions, and 1 fo

Page 21

22[006]-[008] Special Access Codes These sections require 4 or 6 digits to be entered. [006] - Installer Code Installer Lockout Enable . . . . . . .

Page 22

Programming Sections: 5.3 Basic Programming PWS Sect 32310 Latched System Event (Strobe) This output will activate when any of the selected system eve

Page 23 - 4.3 Function Keys

iiNew FeaturesPC5200 SupportThe PC5010 CP-01 v3.1 and higher supports the new PC5200 Power Supply module. See PC5200 Power Supply Output Module, Pg 2.

Page 24

24[012] - Keypad Lockout OptionsThe panel can be programmed to ‘lockout’ keypads if aseries of incorrect access code entries is made. After theNumber

Page 25 - Sect Item Sect Item

Programming Sections: 5.3 Basic Programming PWS Sect 325Option Definition On/Off Description2 Bell During Auto-armON Bell Squawk During Auto-arm Enabl

Page 26 - 5.1 For the Record PWS Sect 1

26Option Definition On/Off Description7 Telephone Line Monitor ON Telephone Line Monitor enabled. The TLM function will be active and the system will

Page 27 - Option Zone Type Description

Programming Sections: 5.3 Basic Programming PWS Sect 327Option Definition On/Off Description3 Audible RF Jam Trouble BeepsON Audible RF Jam Trouble Be

Page 28 - •Bell Time-out

28Option Definition On/Off Description2 Verbal Door Chime ON Verbal Door Chime Is Enabled. The system will verbally annunciate the zone (or programmed

Page 29

Programming Sections: 5.4 Advanced Programming PWS Sect 429[020] - Keypad Zone Assignment Assigning Keypad ZonesEach keypad has a zone input to which

Page 30

30times. If the Auto-arm is postponed, arming or disarmingthe panel will not affect the postpone sequence. [176] - Cross Zone/Police Code TimerThis op

Page 31

Programming Sections: 5.6 Communicator Programming PWS Sect631Some of the Programmable Output options are also select-able by partition see Section 5

Page 32

32disarmed and report to the central station. All other zonetypes will only go into alarm if the panel is armed.Reporting codes can be one or two digi

Page 33

Programming Sections: 5.6 Communicator Programming PWS Sect633[342]-[343] - Opening (Disarming) Reporting Codes Access Codes 1-32The panel will trans

Page 34

iiiPC5010 CP-01 Installer Programming Quick Reference Chart SIA False Alarm ReductionMinimum requirement system for SIA-FAR Installations :• 1 PC5010

Page 35

34Installer Lead In:Installer Lead In:Installer Lead In:Installer Lead In: a reporting code will be sent to the cen-tral monitoring station when Insta

Page 36

Programming Sections: 5.6 Communicator Programming PWS Sect635Pager FormatThe Communicator Format Communicator Format Communicator Format Communicator

Page 37

36• SIA - This format uses 300 Baud FSK as the communi-cation medium. The account code can be 4 or 6 hexa-decimal digits in length, all reporting code

Page 38

Programming Sections: 5.6 Communicator Programming PWS Sect637[378] - Test Transmission Time of DayProgram the time of the test transmission in this s

Page 39

38OFF LINKS is backup of Land Line(s). The control panel will dial through the LINKS if the panel is having difficulty communicating over the phone li

Page 40

Programming Sections: 5.6 Communicator Programming PWS Sect639 [390]-[393] LINKS PreamblesDownloading can be performed through the LINKS1000cellular

Page 41

40(Downloading Telephone Number) . . . . . . . . . . . . . . .Section [490]Communicator Call Direction Options. . . . . . Section [351] to [376]Call L

Page 42

Programming Sections: 5.8 Programmable Output Programming PWS Sect 841NOTE: To perform downloading via the T-Link module,Option [1], Section 401 must

Page 43

42[551]-[564] PGM Partition AssignmentThe PC5010 CP-01 has an 8-bit toggle field per output thatdetermines which partitions the output is assigned to

Page 44

Programming Sections: 5.9 International Programming PWS Sect 943 [701] FIRST INTERNATIONAL OPTION CODESOption International Code On/Off Description1

Page 45

ivTable of ContentsSection 1: Introduction 11.1 About the PC5010 CP-01 System ... 11.2 About the PC5010 CP-01 Manual S

Page 46

44[703] - Delay Between Dialing AttemptsFor standard (force) dialing, the panel will go off-hook,search for dial tone for 5 seconds, hang-up for 20 se

Page 47

Programming Sections: 5.11 Special Installer Instructions PWS Sect 1145[903] - Module Supervision FieldWhen this mode is entered, the system will disp

Page 48 - PGM Output Types [19]-[22]

46[995][Installer Code] - Restore Escort5580(TC) Factory Default ProgrammingWhen this section is successfully entered, all program-ming for the Escort

Page 49

47Section 6: Listing Requirements6.1 UL Listed Commercial and Residential InstallationsThe installation requirements listed below mustbe met for the f

Page 50 - PC5108L Installation Manual

48Appendix A: Reporting CodesThe following tables contain Contact ID and AutomaticSIA format reporting codes. For more information onreporting code fo

Page 51

49Section # Reporting Code Code Sent When...Dialer Direction*Automatic Contact ID CodesSIA Auto Reporting Codes**[344] Special Opening Opening (disarm

Page 52 - Installation Man

50Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when usingthe standard (non-

Page 53 - Installations

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use th

Page 54 - Appendix A: Reporting Codes

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system users, it is you

Page 55

NOTES

Page 56 - Codes (as per ADEMCO):

vPC5010 CP-01 Wiring DiagramNOTE: Remove CON1 when using PGM2for 2-wire smoke

Page 57 - FCC COMPLIANCE STATEMENT

PC5010 CP-01 Module CompatibilityModule Compatible? CommentsClassic Escort (VPM-1) NoDLM-1 NoDLM-4 v1.x NoDLM-4 v1.0L YesDLM-7 NoEscort5580 v3.0 Yes

Page 58 - Limited Warranty

1Section 1: Introduction1.1 About the PC5010 CP-01 SystemThe PC5010 CP-01 is a high end security system. It sup-ports up to 32 zones, 2 separate parti

Page 59

2Digital Communicator Specifications:• Supports all major formats including SIA, Contact ID,and Residential Dial• Split reporting of selected transmis

Page 60

Introduction: 1.4 Additional Devices3PC5936 Audio Interface ModuleThe PC5936 audio interface module provides paging,intercom, baby listen-in and door