DSC Power8 PC5OO5 Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Systèmes de contrôle d'accès de sécurité DSC Power8 PC5OO5. DSC Power8 PC5OO5 Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 46
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
PC5O1O
Version 2.O (UL)
DLS-3 version 1.3 or later
WARNING
This manual contains information on limitations regarding product use and function and
information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
Installation
Manual
Vue de la page 0
1 2 3 4 5 6 ... 45 46

Résumé du contenu

Page 1 - Installation

PC5O1OVersion 2.O (UL)DLS-3 version 1.3 or laterWARNINGThis manual contains information on limitations regarding product use and function andinformati

Page 2 - WARNING Please Read Carefully

G E T T I N G S T A R T E D6Bell Output Terminals - BELL+ and BELL-These terminals provide up to 3 Amps of current at 12 VDC (rated 11.6-12.6 VDC for

Page 3 - Table of Contents

G E T T I N G S T A R T E D72.3 Wire Routing for Power & Non-Power LimitedAll wiring entry points are designated by the arrows. All circuits are

Page 4 - Hookup Diagram

G E T T I N G S T A R T E D8• PC5921 EXT/R Door Box Audio Station: 35 mA • LCD5502Z2 Keypad: 25 mA• PC5108 Zone Module: 35 mA • LCD5501Z32-433: 260m

Page 5 - System Introduction

G E T T I N G S T A R T E D9Step 1 - Enter Installer Programming.Step 2 - Press [000] for Keypad Programming.Step 3 - Enter [1] to [5] to select Func

Page 6 - 1.2 Additional Devices

G E T T I N G S T A R T E D102.10.2 Single End Of Line (EOL) Resistors (5600ΩΩΩΩΩ) NORMALLY CLOSEDCONTACT WITH5600 Ω END OF LINERESISTORANY ZTERMINAL

Page 7

G E T T I N G S T A R T E D112.10.6 Keyswitch Zone WiringΩΩZones may be programmed to be used as keyswitcharming zones and must be wired according to

Page 8 - 1.3 Out of the Box

Keypad CommandsS E C T I O N 312All keypads provide complete information and control of the alarm panel. The panel can be completely pro-grammed via

Page 9 - Getting Started

K E Y P A D C O M M A N D S133.3 Auto BypassWhen the system is armed and any zone or zone(s) on the system have been programmed as Stay/Away thepanel

Page 10 - G E T T I N G S T A R T E D

K E Y P A D C O M M A N D S14A description of the various troubles are as follows:Trouble [1] - Service Required This light will be on if any of th

Page 11

K E Y P A D C O M M A N D S15[✱]+[4] Door Chime On/OffIf enabled the keypad will beep 5 times rapidly when a zone is tripped and restored. The panel

Page 12 - 2.7 Keypad Assignment

LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc

Page 13 - 2.10 Zone Wiring

K E Y P A D C O M M A N D S16[✱]+[6] User FunctionsThis keypad command can be used to program several different functions. The following are the item

Page 14 - 5600Ω (contact closed) Secure

K E Y P A D C O M M A N D S17Special Note: [✱] [7] [2] – Command Output Option #2:Press [✱] [7] [2] [Access Code, if required] to activate all output

Page 15 - 2.11 Keypad Zones

K E Y P A D C O M M A N D S183.5.1 Function Key OptionsThe following is a list of Function Key options available:[00] - Null KeyThe key is not used a

Page 16 - Keypad Commands

K E Y P A D C O M M A N D S19[18] Identified Voice Prompt HelpThis feature can only be programmed if both the Escort5580 and the PC5928 Audio Matrix

Page 17 - 3.4 [✱] Commands

How to ProgramS E C T I O N 420The following section of the manual describes how to enter Installer Programming and how to program the various sectio

Page 18 - LCD keypad

H O W T O P R O G R A M21[1] to enter A[✱] to return to decimal mode (Ready light is solid)[3] to enter the digit 3[0] to enter the digit 0 as a fil

Page 19 - K E Y P A D C O M M A N D S

Program Descriptions22S E C T I O N 5The following section explains all the programmable features including how the feature operates, options thatper

Page 20

P R O G R A M D E S C R I P T I O N S23Do not wire 24-Hour Supervisory zones on keypad zone terminals.[10] 24 Hour Supervisory Buzzer Zone Whether

Page 21 - 3.5 Function Keys

P R O G R A M D E S C R I P T I O N S24Wireless Zone Determines if the zone is a wireless zone or a hardwired zone. Allows the panel to generate lo

Page 22

P R O G R A M D E S C R I P T I O N S255.6 Communicator - Reporting FormatsEach central station phone number of the panel can be programmed to report

Page 23

Table of ContentsiPC5010 Control Panel Hookup Diagram ... iiSection 1 - System Introduction1.1 Specifications ...

Page 24 - How to Program

P R O G R A M D E S C R I P T I O N S26Communicator Format ... Section [360]SIA Sends Automatic Reporting Cod

Page 25 - 4.5 Viewing Programming

P R O G R A M D E S C R I P T I O N S275.7.4 OpeningsThe panel will transmit an Opening Reporting Code to indicate a Partition(s) has been disarmed.

Page 26 - Program Descriptions

P R O G R A M D E S C R I P T I O N S28A General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing from theKey

Page 27 - 5.2 Zone Attributes

P R O G R A M D E S C R I P T I O N S29The panel will immediately go on line and begin the download process unless the Call Back option is enabled. I

Page 28 - 5.3 Communicator - Dialing

P R O G R A M D E S C R I P T I O N S30• 8 low current outputs available with the PC5208 Output Module• 4 high current outputs available with the PC5

Page 29

P R O G R A M D E S C R I P T I O N S31[11] System Tamper The PGM Output will activate when any Tamper condition is present and will de

Page 30

P R O G R A M D E S C R I P T I O N S32Attribute [2], Partition 2 controls event is defaulted OFF for all output options.Attribute [3] must be ON (de

Page 31

P R O G R A M D E S C R I P T I O N S33Test Transmission Reporting Codes ... Section [352]Test Transmission Time of Day ...

Page 32 - 5.8 Downloading

P R O G R A M D E S C R I P T I O N S34The event buffer can be viewed three different ways. It can be viewed through an LCD keypad, printed on-site u

Page 33 - 5.10 PGM Outputs

P R O G R A M D E S C R I P T I O N S35If armed, the panel will do nothing until the next day at the Auto-Arm Time, when it will check again.If disar

Page 34

Hookup DiagramP C 5 0 1 0 C O N T R O L P A N E LLCD5501Z32-433CompatibleSystem KeypadsCompatible System Keypads: PC5508Z/KP5508Z, PC5516Z/KP5516Z,P

Page 35

P R O G R A M D E S C R I P T I O N S36must be programmed with a hex decimal “F”.5.26.1 Using LINKS1000 as the Sole CommunicatorThe panel can be prog

Page 36 - 5.13 Test Transmission

P R O G R A M D E S C R I P T I O N S37Step 3 - Enter Sections [82], [83], [84] and [85] to enable or disable supervision.The wireless zone attribute

Page 37 - 5.16 Event Buffer

P R O G R A M D E S C R I P T I O N S385.32.1 Factory Default Main Panel (Hardware)Step 1 - Remove AC and battery from the panel.Step 2 - Remove all

Page 38 - 5.21 Automatic Arming

39SIA Format (Level 2—Hardcoded)This format will send the Account Code along with itsdata transmission. At the receiver, the transmissionwould look si

Page 39 - 5.25 Keypad Tampers

40REPORTINGV CODES* A/R = alarms/restorals; T/R = tamper/restorals; O/C = openings/closings; Maint. = maintenance;Misc. = miscellaneous; Test = test t

Page 40 - 5.27 Wireless Expansion

UL Listed Commercial and Residential InstallationsThe installation requirements listed below must be met for the following grades of service.Grade A L

Page 41 - 5.32 Default (Factory)

©2002 Digital Security Controls Ltd.Toronto, Canada • www.dsc.comTechnical Support: 1-800-387-3630Printed in Canada 29002711 R005FCC COMPLIANCE S

Page 42 - 5.34 Walk Test (Installer)

1System IntroductionS E C T I O N 11.1 SpecificationsControl Panel SpecificationsFlexible Zone Configuration:• 8 Fully Programmable Zones• 38 Access

Page 43 - Reporting Codes

S Y S T E M I N T R O D U C T I O N2Additional Features• Auto Arm by Partition at Specified Time• Keypad Activated Alarm Output and Communicator Test

Page 44 - REPORTINGV CODES

S Y S T E M I N T R O D U C T I O N31.2.4 PC5100 Addressable Service Interface ModuleThe PC5100 will allow addressable multiplex loop devicesto be ad

Page 45 - Zone Reporting Codes

S Y S T E M I N T R O D U C T I O N41.2.10 LINKS1000 Cellular CommunicatorThe LINKS1000 Cellular Communicator provides an efficient, cost-effective m

Page 46 - FCC COMPLIANCE STATEMENT

Getting StartedS E C T I O N 25The following sections provide a complete description of how to wire and configure devices and zones.2.1 Installation

Commentaires sur ces manuels

Pas de commentaire