PowerSeries - PC1616/PC1808/PC1832/PC1864
24
Section [601] to [608] Additional Reporting Codes
Program the reporting code for all events to be transmitted. For description of when each reporting event will be transmitted, refer to
Appendix A – Reporting Codes. The panel also supports Automatic SIA and Automatic Contact ID reporting. Program data [00] to disable
the reporting of an event. If any other data is programmed (Data [01] to [FF]) the panel will automatically generate the correct reporting
event when transmitting to the central station. For all formats excluding Automatic SIA and Automatic Contact ID, the panel will not attempt
to report an event if data [00] or data [FF] is programmed for the reporting code.
Section [681] to [688] Auto-Disarm Schedules
Program the time to auto-disarm (Section [681] for Partition 1, Section [682] for Partition 2 etc.) for each day of the week. Each Section has
seven, 4-digit entries, two digits for the hour, two digits for the minute, for Sunday through Saturday. Program using the military format (for
example, to auto arm at 8:00 pm program data [20][00]). Valid entries are [00][00] to [23][59] – program [99][99] to disable auto disarming
Section [691] to [698] Auto-Disarm Holiday Schedule
Program the dates to be used for Auto-Disarm holiday schedule (Section [691] for Partition 1, Section [692] for Partition 2 etc.) Each Section
has fourteen, 6-digit entries, two digits for the month, two digits for the day and two digits for the year.The panel will not disarm on the pro-
grammed dates. The format of entering the date is MMDDYY. Program [99][99][99] to disable Auto-Disarm holiday schedule.
Section [700] Automatic Clock Adjust
Program the number of seconds for the last minute of the day. This can be used to make minor corrections to the clock if the AC frequency is
not reliable. Valid entries are [01] to [99].
Section [701] First International Option Code
Section [702] Second International Option Code
Option Description
[1] ON: configures the system for 50Hz AC. OFF: configures the system for 60Hz AC.
[2] ON: the system uses the internal crystal for the internal panel clock. OFF: the system uses the AC frequency for the internal panel clock.
[3] ON: the system will inhibit arming if a Low Battery or AC trouble condition is present. OFF: arming will not be inhibited.
[4] ON: all Tamper troubles will latch and arming will be inhibited. Enter Installer Programming to clear the trouble condition and return to
normal operation. OFF: tamper troubles will not latch and will not inhibit arming.
[5] ON: all access codes are 6 digits long. OFF: all access codes are 4 digits long.
[6] ON: the system will hang up if a busy tone is detected. This attempt is not counted towards the Maximum Dialing Attempts programmed.
OFF: the panel will not detect busy tones.
[7] ON: the system will charge the battery at approximately 700mA. OFF: the system will charge the battery at 400mA.
[8] ON: the system will abort a DLS session, Escort access, Listen In/Two-way session if a new central station communication event occurs.
OFF: non-critical events (Test transmission, Periodic Test and System Test) will not abort the session. Events will be communicated after
the session is complete.
Option Description
[1] ON: the communicator uses 33/67 make/break ratio when pulse dialing. OFF: the system uses 40/60 make/break ratio.
[2] ON: the system dials regardless of the presence of dial tone after the first attempt. OFF: the system dials only if dial tone is detected.
[3] ON: changes the Test Transmission Cycle Time to minutes. OFF: sends a Test Transmission after the programmed number of days.
[4] ON: the system accepts 1600Hz handshake pulse formats. OFF: the system accepts 1400Hz or 2300Hz handshakes.
[5] ON: the system generates a tone for 500mS every 2 seconds indicating digital equipment is making the call vs. a voice call.
OFF: the system does not generate a tone.
[6] ON: the tone generated (2100Hz.) indicates that digital equipment is making the call. OFF: the tone is 1300Hz.
[7] ON: the DLS down loading window is 1 hour. OFF: the DLS downloading window is 6 hours.
[8] ON: the system activates the bell output if a Failure to Communicate trouble occurs while the system is armed.
OFF: the system does NOT activate the bell output if a Failure to Communicate trouble occurs while the system is armed.