Changing Brightness
1.Press More > User Options > Keypad Config >
Brightness.
2.Use the slide bar to adjust brightness to the
desired setting.
3.To exit press the Back or Home button.
Changing the Volume
1.Press More > User Options > Keypad Config >
Volume Settings.
2.Use the slide bar to adjust volume to the desired
setting.
3.To exit press the Back or Home button.
Installer Keypad Configuration
There are several configuration options available
for the keypad (see below). Keypad configuration
options are set by using the touchscreen to navi-
gate menu screens. For information on program-
ming the rest of your security system, please refer
to your system’s Installation Manual.
Keypad Options
Press More > Installer Options [Installer Code] >
Keypad Options to open a list of programmable
options for the keypad. Use the arrow keys on the
right side of the screen to scroll through the list of
options. Press the switch underneath each option
to toggle the state of the option.
• Fire Key Enable or Disable (Default = Enabled)
• Auxiliary Key Enable or Disable
(Default = Enabled)
• Panic Key Enable or Disable
(Default = Enabled)
• Clock Screen Saver Enable or Disable
(Default = Enabled, 1 minute timeout)
• Clock Display 24 hrs or AM/PM
(Default = AM/PM)
• Power LED Enable or Disable
(Default = Disabled)
• Power LED Indicates AC is Present or Absent
(Default = Present)
• Local RF Jam Enable or Disable
• (Default = Enabled)
• Instant Stay Enable or Disable (Default = Disable)
Displaying Keypad Software Versions
1.Press More > Installer Options [Installer Code]
>Versions.
2.Examine the version information displayed on
the screen.
3.To exit press the Back or Home button.
Zone Label Programming
The WTK5504 is programmed with default labels
to identify each zone (e.g., the label for zone 5 is
‘Zone 05’). Use this section to assign a meaning-
ful name to each zone (e.g., ‘Living Room
Motion Sensor’). The WTK5504 features a data-
base of words commonly used when describing
zones that can be combined to create a label.
1.Enter Label Programming by pressing More >
Installer Options [Installer Code] > Labels Pro-
gramming > Zone Labels.
2.Use the up and down arrows to navigate to the
desired zone and press the current zone label.
3.Use the alphabet at the top of the screen to
select the first letter of the desired label.
4.Use the up and down arrows to scroll through
the list of words starting with the selected letter
and press the word to add it to the zone label.
5.Repeat steps 3 and 4 to add additional words to
the label as needed until or the character limit
(28) is reached.
6.Press Save to save the label and return to the
Labels Programming screen.
Label Library
The Label Library is a database of words com-
monly used when programming labels. Individual
words can be combined as needed. e.g., Front +
Door. Each line of the display supports a maxi-
mum of 14 characters.
Enable Verbal Chime by Zone
The WTK5504 allows the installer to select which
zones announce verbal chime. By default, verbal
chime is disabled for all zones. To enable verbal
chime, press More > Installer Options [Installer
Code] > Verbal Chime Zones. Use the arrows at
the right side of the screen to scroll through a list
of zones and press the switch button beside the
zone label to enable/disable verbal chime for that
zone.
Broadcasting Labels
Label programming is done using Keypad 1 or, if
using the SCW9055/SCW9057, from the main
control panel. Labels are broadcast to all other
WTK5504 keypads enrolled on the system.
Perform the following in order to broadcast
labels:
1.Program Keypad 1 or the SCW9055/9057 con-
trol panel completely.
2.Press More > Installer Options [Installer Code]
> Labels Programming > Broadcast Labels at
the keypad that was programmed.
NOTE: This operation may take several min-
utes.
3.To exit press the Back or Home button.
NOTE: Label broadcast from Keypad 1 is
only compatible with other WTK5504 key-
pads (PC9155 and Power v4.6+ only).
End User Instructions
After completing the installation of the
WTK5504, it is the installers responsibility to
inform the end user of the following:
• Clean the touchscreen with a soft cloth and iso-
propyl alcohol. Use of other cleaners such as
water, ketone (e.g., acetone), and/or aromatic
solvents (e.g., benzene and toluene) may dam-
age the display.
• Do not attempt to disassemble the LCD Module.
• Do not subject the touchscreen to mechanical
shock (e.g., dropping or striking). Mechanical
shock could damage the glass display.
• If the touchscreen is damaged, the liquid crystal
fluid inside could leak out. Avoid contact with
the liquid crystal fluid. If the liquid crystal fluid
comes into contact with your skin or clothes,
promptly wash it off using soap and running
water. Seek medical care.