20
[1]*Light off= Communications are enabled
Light on= Communications are disabled
[2]*Light off = Restorals follow zones
Light on = Restorals sent on bell time out
[3]*Light off= No alarms are displayed while panel is armed
Light on = Alarms are displayed while panel is fully armed
[4]*Light off= Panel dials pulse (Rotary dialing)
Light on = Panel dials DTMF (Touch tone dialing)
[5]*Light off = Zones 1 to 8 use end-of-line-resistors
Light on = Zones 1 to 8 use normally closed zones
Note: For UL residential installations. When zones are
programmed as normally open (not supervised) they
shall be located within 3 feet of the control unit. Other
initiating circuits must be end-of-line supervised.
For UL commercial installations, zones must be end-of-
line supervised.
[6]*Light off= Keypad panic [P], bell is silent
Light on = Keypad panic [P], bell is audible
(See Keypad Zones.)
[7] Light off = Call 1st phone number with backup to 2nd
phone number if unsuccessful for 8 attempts
* Light on = Becomes call 1st phone number only
(See section [35].)
Note: Do not program backup to 2nd phone number
if
no 2nd phone number is programmed.
[8]* Light off= 16th code becomes normal access code
Light on = 16th code is maid's code (One Time Use code)
(Access codes are programmed with [✱][5] command)
* is default condition.
[16] 2nd System Option Code
Use same method of programming as used in section [15].
[1]*Light off = Partial closings not identified
Light on = Partial closings identified
(Bypassed zones will be identified with their alarm
transmissions between the partial closing code and the
closing code.)
[2]*Light off = Master code changeable
Light on = Master code changeable by installer
only
(See [✱]+[5] User’s Programming Commands page 9)
[3]*Light off = Disable bell squawk
Light on = Enabled bell squawk upon arm or disarm
(1 burst on Arm/2 bursts on Disarm)
[4]*Light off = PC16OUT module disabled
Light on = PC16OUT module enabled
(Module which provides 16 voltage outputs to indicate
panel conditions. See distributor for details.)
[5]*Light off = TLM trouble, audible bell when armed
Light on = TLM trouble only, armed or disarmed
(TLM = Telephone Line Monitoring)
[6]*Light off = Accepts 2300Hz (standard) handshake
Light on = Accepts 1400Hz handshake for Radionics
formats #3, 4, B and C in section [29]
(See Radionics format description page 21).
[7]*Light off = TLM enabled
Light on = TLM disabled
(TLM = Telephone Line Monitoring)
[8]*Light off = No access code required for zone bypassing
Light on = Use [✱]+[1]+[Access Code] for zone
bypassing (shunting)
* is default condition.
[17] 3rd System Option Code
[1]*Light off = Bell squawks once every 10 seconds during
auto-arm
Light on = Only the buzzer will sound during an auto-arm
(See Auto-arm, [✱]+[6]+[Master Code]+[2])
[2]*Light off = Acknowledge AC as a valid trouble
Light on = AC is excluded from trouble group
[3]*Light off = Zones are active on power up
Light on = 60 second bypass of zones on power up
[4]*Light off = Any key will abort the auto-arm
Light on = Auto-arm cancel requires a 4 digit access
code
(See Auto-arm, [✱]+[6]+[Master Code]+[2])
[5]*Light off = Home-Away zones act as interior zones when
active
Light on = Home-Away zones act as delay zones when
active
(See Zone Type 3, section [14].)
[6]*Light off = Auxiliary delay zones arm same as other
zones
Light on = Auxiliary delay zones can be force armed
(See Zone Type 7, section [14].)
[7]*Light off = Transmission counter for swinger shutdown
reset upon arming
Light on = Transmission counter reset every 24 hours at
midnight
(See section [22].)
[8]*Light off = Bypass status shown when disarmed only
Light on = Bypass status shown when armed or
disarmed
(See Zone Bypassing.)
* is default condition.
[18] 4th System Option Code
[1]*Light off= Quick exit disabled
Light on= Quick exit enabled ([✱]+[0] when armed)
(See Quick Exit.)
Note: Quick exit shall not be enabled on UL listed
systems.
[2]*Light off= Bell responds normally
Light on= Bell pulses always
(Bell pulses for fire or alarm)
[3]*Light off= Bypassed zones not displayed when armed
Light on = Bypassed zones displayed when armed
(See Zone Bypassing.)
[4]*Light off = Keypad LEDs always active
Light on = Keypad LEDs turn off after 2 minutes of no key
entry. Any alarm, entry delay, or keypress will
reactivate LEDs.
Note: This feature must not be used with an LCD
keypad.
[5]*Light off= Partial closing transmission on auto-arm
disabled
Light on= Partial closing transmission on auto-arm
enabled
(See Auto-arm, [✱]+[6]+[Master Code]+[2])
[6]*Light off= Keypad buzzer audible indication of panic