DSC Classic PC580 Manuel d'instructions Page 36

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 79
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 35
36
PC5010 - Version 1.X
Make note of the Downloading Access Code programmed in Section [403] and the
Panel Identifier Code programmed in Section [404]. You must enter these values into
the DLS account. Make sure that the Panel Identifier Code is not the same as the
Identifier Codes in other work files.
To Have the Computer Call the Control Panel
1.
In
Section [401]
, enable Downloading Answer by turning
ON
Light [1]
.
2.
You can enable the Callback feature by turning
ON Light [3]
in
Section
[401]
, if you require this security feature. If you enable this feature, you must
also program the telephone number of the downloading computer in
Section [402]
.
Note that the “Double Call” technique is the only method available to
connect to the PC5010 for downloading.
PC550 - Version 1.X
Make note of the Downloading Access Code programmed in Section [12]. This value
must be entered into the account.
To Have the Computer Call the Control Panel
In
Section [06]
, enable Answer Enable by turning
ON
Light [3]
.
Note that the “Double Call” technique is the only method available to
connect to the PC550 for downloading.