El
161
“Slow” Zone Response Time
(01 to 99 x
IO
ms) Location
[5]
determines the “slow” zone response time;
this time is programmable from 10 ms to 990 ms. The default Slow Zone Response Time is 500 ms.
NOTE:
The fast zone response time is fixed at
10
ms.
Test Transmission Cycle Time
(01 to 99 days) Location
[6]
determines the frequency, in days, of the test
transmission made through the communicator or by calling the downloading computer. The default setting is
30 days; refer to Section
[
14]3rd
System Option Code, Light 3 for information on enabling the test transmission.
[i83
Auxiliary Delay Zone Entry/Exit Times
Zones programmed as Type
[7]
in Section [I
l]
will use the Auxiliary Entry and Exit Delays.
Enter two 3-digit numbers in Section
[18]
to determine the Auxiliary Entry Delay and the Auxiliary Exit Delay.
The default setting for the Auxiliary Entry Delay is 45 seconds; the default setting for the Auxiliary Exit Delay is
60 seconds. Each time may be programmed within the range of [000] to
[255]
seconds.
If91
System Clock Times
[19]
as
Times for Automatic Arming Time of Day and Test Transmission Time of Day are entered in Section
4-digit numbers. Do not press the
[#]
Key during data entry.
The default setting for both times is
[9999];
programming these times as
[9999]
disables the features
time of day in the 24-hour clock format must be programmed for these features to function.
Avalid
Test Transmission or Periodic Downloading is enabled in Section
[14],
3rd System Option Code, Light 3. The
cycle time in days for the test transmission or periodic downloading is set in Section
[17],
System Times. For
atest
transmission using the communicator, an automatic test code should be entered in Section
[lo].
For
either
feature, a valid transmission time must be entered in Section
[19].
NOTE:
If the Auto-Arm time or the Test Transmission time has a valid time entered when power is applied to
the control panel, then a loss-of-time trouble will be generated. Be sure to clear the trouble condition and reset
the system clock.
II
1881
Installer’s Code
It
is recommended that the Installer’s Code be changed when the control panel is installed. Program a new
4-digit code in this section. Only use digits [0] through
[9]
as code numbers; do not press the
[a]
or
[#]
Keys
during code entry. If an error is made in entering the code, complete entry of the 4 digits and then enter the
section again to correct the code.
[2f3
Master Code
It
is recommended that a new Master Code be programmed when the control panel is installed. Consult with
the system’s users to determine the new Master Code and program the new
4-digit
code in this section. Refer
to Section
[20]
for programming information.