Section 16: Diagnostics and Troubleshooting
41
SECTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
battery trouble occurs, the panel will not restore the trou-
ble until it has been viewed using the [*][2] trouble dis-
play. The trouble will not be restore until it has been
viewed, even if the cause of the trouble has been physi-
cally restored. If the option if turned off, the panel will
restore these troubles as soon as the trouble condition is
physically restored. The option is off by default.
Trouble conditions can be transmitted to the central sta-
tion, if programmed (see Section 5.7 “Reporting Codes”).
To view trouble conditions, press the [*] key then [2]. The
keypad display will indicate the trouble. All possible
trouble displays and a description of each is listed below.
16.5System Fault Squawk
If the Sys.Flt.Squawk option is turned on, when the sys-
tem detects a zone tamper, zone fault or a module
tamper, all the burglary bell outputs will squawk once
every 5 seconds. The “squawks” will be silenced when
the alarm is silenced or a key is pressed on that partition.
By default this option is off.
Display Trouble Condition
Battery Trouble The battery connected to the control panel is low.
AC Trouble There is a power failure (keypad will be silent).
Aux Supply
Troub
The AUX, SAUX+ or PGM terminals on the alarm
control panel are overloaded
TLM Trouble There is a trouble with the telephone line.
TLM TBL Line #1 There is a trouble on telephone line 1 (only gener-
ated when using the PC4701 Fire Module).
TLM TBL Line #2 There is a trouble on telephone line 2 (only gener-
ated when using the PC4701 Fire Module).
FTC Trouble The alarm control panel can no longer communicate
with the central monitoring station. The trouble is
generated after the programmed failed communica-
tion attempts. If a later attempt to communicate is
successful, the trouble is cleared.
Bell CCT Trouble The bell circuit is open (PC4020 or PC4702).
Fire Trouble A fire loop is open circuit (indicated by the trouble
sound; cannot be silenced). If the alarm control
panel loses communication with any expansion mod-
ule, all Fire/Burglary outputs will activate once every
10 seconds until a keypress is made, or module com-
munication is restored.
2 Wire Smoke The fire zone on a PC4701 Fire Module is open. The
keypad will display “2-Wire Smoke” until the trouble
is restored.
Ground Fault The earth ground (EGND) connection is shorted to a
positive voltage source or shorted to a non-earth
ground potential.
Waterflow The Waterflow zone on a PC4701 Fire Module is
open. The keypad will display “Waterflow TBL” until
the zone trouble is restored.
Loss of Time This trouble is cleared when the system’s time and
date are reset.
Module Com
Fault
The panel has lost communications with a module.
Check to see if the module is connected properly,
then do a system reset. Only qualified service per-
sonnel can perform this function.
Combus Low
Pwr
Modules are not getting enough voltage from the
Combus. Check for proper connection of Combus, or
repower the Combus, if required. Only qualified ser-
vice personnel can perform this function.
4204 Battery TBL The battery connected to any PC4204 relay output
module is low (module number indicated in report-
ing code transmission and event buffer).
4204 AC Trouble A PC4204 relay output module loses incoming AC
power (keypad will be silent).
4204 AUX Trou-
ble
The Auxiliary supply on any PC4204 relay module is
overloaded.
Display Trouble Condition
LINKS Trouble A LINKS unit has one or more of the following trou-
ble conditions: loss of AC power, low battery, loss of
cellular communication or a tamper fault.
DLS Fault TBL The control panel has failed to complete communi-
cations with the downloading computer.
Device Fault A wireless zone has failed to report a zone supervi-
sory (press [*] to view which zone).
Device Low Batt A wireless zone has a low battery (press [*] to view
which zone/device).
Device Tamper A wireless zone has a tamper condition (press [*] to
view which zone).
Automation
Fault
The ESCORT4580 loses communication with the
Automation Output control module. If there is an
AC trouble present, the panel will not transmit the
Automation Fault reporting code to the central sta-
tion.
4820 Battery
Trouble
The battery connected to a PC4820 module is low.
4820 AC Trouble A PC4820 module has lost AC power.
4820 Lock Trou-
ble
A PC4820 module has a trouble with one of its lock-
ing devices. A lock trouble occurs when the lock
power output is overloaded or the lock power fuse
has failed.
4820 Aux Trou-
ble
The PC4820’s Auxiliary (AUX) supply is overloaded.
4820 Rdr Pw TBL A PC4820 module’s card reader power output is
overloaded or the reader power fuse has failed.
Smoke Low Sens A WLS906 Smoke Detector’s sensitivity is low.
4164 Signal Tbl Wireless zone transmissions are not being received
by the PC4164-RS wireless receiver.
RF Jam Detected Wireless device transmissions not being received by
the PC4164-RS wireless receiver
4702 AC TBL The PC4702 module has lost AC power.
4702 Battery TBL The battery connected to the PC4702 is low.
Bells Silenced Fire alarm signals have been silenced. Trouble will
clear when the system is reset (enter access code)
Insp. Test Active The fire inspector's test has been initiated. Trouble
will clear when the test mode is disabled.
Printer Off-Line The printer connected to the PC4400 module is off-
line.
PC4400 Trouble The DVAC line from central station is not present,
the module has failed internal diagnostics or DVAC
communications have been shut down.
Vue de la page 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 51 52

Commentaires sur ces manuels

Pas de commentaire

Zanussi ZEM6740BBA podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Płyty grzewcze Zanussi ZEM6740BBA.
Dostarczamy 1 pdf podręczników Zanussi ZEM6740BBA do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Płyty grzewcze Zanussi

Modele Rodzaj dokumentu
ZEV8648XBA Instrukcja Użytkownika    ZANUSSI ZEV8648XBA User Manual, 32 strony
ZEV6940XBV Instrukcja Użytkownika   ZANUSSI ZEV6940XBV User Manual [ru] , 12 strony
ZVH66F Instrukcja Użytkownika   ZANUSSI ZVH66F User Manual, 12 strony
ZK 641X ZANUSSI Instrukcja Użytkownika   ZANUSSI ZK 641X ZANUSSI Benutzerhandbuch, 20 strony
ZGL62ITX Instrukcja Użytkownika   ZANUSSI ZGL62ITX User Manual, 20 strony
ZGF642X Instrukcja Użytkownika   ZANUSSI ZGF642X User Manual, 32 strony
ZGF640ITX Instrukcja Użytkownika   ZANUSSI ZGF640ITX User Manual [sk] , 28 strony
ZEI8640XBA Instrukcja Użytkownika   ZANUSSI ZEI8640XBA User Manual [en] , 20 strony
ZKT663LX Instrukcja Użytkownika    ZANUSSI ZKT663LX User Manual, 52 strony
ZGG66414PA Instrukcja Użytkownika     ZANUSSI ZGG66414PA User Manual, 48 strony
ZK64X A68 Instrukcja Użytkownika   ZANUSSI ZK64W User Manual, 12 strony
ZGO62414BA Instrukcja Użytkownika   ZANUSSI ZGO62414BA User Manual, 16 strony
ZGRX2504-7 Instrukcja Użytkownika   ZANUSSI ZGRX2504-7 User Manual, 17 strony
ZKT 621LN ZANUSSI Instrukcja Użytkownika       ZANUSSI ZKT 621LX ZANUSSI Brugermanual, 172 strony
ZKT863LX 69B Instrukcja Użytkownika   ZANUSSI ZKT863LX 69B User Manual, 32 strony
PIANO X KIT ZXL638IW Instrukcja Użytkownika   ZANUSSI PIANO X KIT ZGL648IX User Manual [de] [fr] [nl] , 10 strony
ZEV6140XBA Instrukcja Użytkownika   ZANUSSI ZEV6140XBA User Manual [de] , 12 strony
ZK640LX Instrukcja Użytkownika   ZANUSSI ZK640LX User Manual, 14 strony
ZA600F Instrukcja Użytkownika   ZANUSSI ZA600F Benutzerhandbuch, 16 strony
ZKT863LX Instrukcja Użytkownika   ZANUSSI ZKT863LX User Manual, 32 strony