3
Communicator
Communicates using the SIA 1986, or the Contact ID format
Communicates to up to three telephone numbers
Each telephone number can be backed up by a LINKS1000
cellular communicator
With the PC6442 and PC6443 modules, uses the Backbone
to communicate over a dedicated connection with alarm
presentation software. Communications are encrypted.
One system and 32 area (account) codes
Hexadecimal numbers available
DTMF and pulse dialing
True dial tone detect
Printer
Can print data on a serial local printer using a PC6400 serial
interface module
Powerful 2.2 amp regulated power supply
776 mA auxiliary supply, 11.6 - 12.6 VDC, when charging a
36Ah battery.
Separately fused for battery, auxiliary supply and bell output
Electronic shutdown protection of the Combus
Supervision for loss of AC power, low battery, electronic
shutdown of modules
Internal clock locked to AC power frequency or optional
crystal time base
Battery
12 volt, 7 to 36Ah minimum rechargeable gel-cell or sealed
lead-acid battery
Normal battery charging current 360mA
High battery charging current (1.4A) available (software
selectable)
Transformer
16.5 VAC, 80VA
Output Voltage
Typically, with normal AC on and a fully charged battery, the
output voltage will be 13.8 VDC. With AC off and the battery
discharging, the voltage will go below 10 volts and then battery
cutoff will occur preventing further discharge. Devices that
require power from the control panel should be capable of
operation over the voltage range of 10 to 14 V
DC.
2 Enclosures
PC4005C cabinet: PC6010 and two modules
PC4003C cabinet: 2- PC6108A modules, 1 - PC6204 module,
1- PC6216 module, or 1 PC6400 module
2.2 Module Specifications
Refer to each module’s Installation Instruction sheet for wiring
and programming information.
PC6108A Expansion Module
8-zone expansion module
Add up to 30 modules for a total of 256 zones on the system
Supports double end-of-line zone loops (5600 ohm resistors)
Connects to control panel via 4-wire Combus
Nominal current draw of 30 mA (from Combus)
AUX+ Output: 12 VDC, 250mA max. (power drawn from
Combus)
Provides Tamper reporting codes
Low Combus supervision
PC6204 High-Current Output Module
4 high-current outputs
Output current 1A, 12VDC
Up to 16 modules on system (up to 64 high-current outputs)
Each output programmable for 1 of 56 options
Connects to control panel via 4-wire Combus
Low Combus supervision
Four programmable relay contacts rated 2A, 30VDC
Minimum 80 VA 16-18 volt transformer required
Minimum 4 Ah battery required, up to 36Ah max.
Current draw: 30 mA (from Combus)
Provides Tamper and Trouble reporting codes
AUX current: 500mA max.
Tamper contact input
PC6216 Low Current Output Module
16-output low-current module
Nominal current draw of 15 mA, plus power required by
outputs
Output current 50mA, 12VDC
Up to 9 modules on system
Can be programmed as alarm or zone annunciators
All 16 outputs can be programmed on each module, 1 of 56
options each
Provides Tamper reporting codes
Connects to control panel via 4-wire Combus
Low Combus supervision
Power drawn from Combus
PC6400 Serial (Printer) Module
True RS-232 technology
Handshake software switches
DTR Protocol
Baud rate: 4800
Connects to control panel via 4-wire Combus
Nominal current draw of 35 mA
Low Combus supervision
Tamper and Trouble reporting codes
Maximum cable length: 200 feet (61 meters)