17
6.3 “Warning - Security Reduced”
Messages
These messages are displayed on the keypad if a user tries to
arm the system when there is a problem with one or more zones
(i.e. a zone is open, in alarm, or has a fault, tamper, seismic fault
or trouble condition).
The following message will be displayed on the keypad:
“Warning - Security Reduced”
If this message is displayed, users can continue arming their
area(s) by pressing the YES button. The keypad then displays
“Warning Confirmed”, and the area(s) are armed.
6.4 Time and Date Display
When the keypad is idle, it will show the time and date. The
clock will show in 24-hour time (00:00 - 23:59), and the date
will show as year/month/day (YY/MM/DD). For example, 1:30 pm
December 13, 1999 will be displayed as 13:30 1999/12/13
The system will automatically adjust for the switch to daylight
savings time in March, and back to standard time in October.
The dates that these changes occur on are programmed in the
Daylight Savings and Standard Time programming sections. See
System Times in the PC6010 Programming Manual for more
information.
If the system is connected to Alarm Presentation Software over
the backbone, the system will get the new time from the
software, and will not follow the Daylight Savings Time /
Standard Time programming sections.
Master users also can reset the time and date through the user
interface. See the Maintenance Manual for more information.
6.5 Keypad Lockout
After a programmed number of incorrect attempts to enter a user
or installer code, the keypad will lock out the user. The lockout
prevents the user from performing any function at any keypad.
The keypad will display “Keypad Lockout is Active” for the
lockout duration. See the “System Options” section in the
Programming Manual for information on programming the
number of incorrect code entries allowed (Total Bad Codes), and
how long the keypad will remain locked out (Lockout Duration).
6.6 Keypad Tampers
If there are tamper plates attached to the PC6501 keypad, you
should enable the Keypad Tampers toggle option. See the
“System Options” section in the Programming Manual.
6.7 Keypad Backlighting
When a user presses a key on the keypad, the keypad
backlighting will increase to the “boost” level. After 30 seconds
of inactivity, the keypad will return to the preset backlight level.
Master and Supervisor users can select the level of (non-boosted)
backlighting in the Keypad Setup section of the user menu.