P R O G R A M D E S C R I P T I O N S
30
Please refer to the Control Panel Wiring Diagram in this manual for wiring instructions.
Only ONE of options [03] Sensor Reset, [04] 2-WOnly ONE of options [03] Sensor Reset, [04] 2-W
Only ONE of options [03] Sensor Reset, [04] 2-WOnly ONE of options [03] Sensor Reset, [04] 2-W
Only ONE of options [03] Sensor Reset, [04] 2-W
irir
irir
ir
e Smoke and [20] [e Smoke and [20] [
e Smoke and [20] [e Smoke and [20] [
e Smoke and [20] [
✱
] [7] [2] Command Output] [7] [2] Command Output
] [7] [2] Command Output] [7] [2] Command Output
] [7] [2] Command Output
Option #2 may be prOption #2 may be pr
Option #2 may be prOption #2 may be pr
Option #2 may be pr
ogrammed on the same system.ogrammed on the same system.
ogrammed on the same system.ogrammed on the same system.
ogrammed on the same system.
[04] 2-Wire Smoke Support (PGM2 Only) PGM2 may be used in conjunction with two-wire smoke detectors.
PGM Output Attributes for PGM2 when used for 2-wirPGM Output Attributes for PGM2 when used for 2-wir
PGM Output Attributes for PGM2 when used for 2-wirPGM Output Attributes for PGM2 when used for 2-wir
PGM Output Attributes for PGM2 when used for 2-wir
e smoke detector suppore smoke detector suppor
e smoke detector suppore smoke detector suppor
e smoke detector suppor
t must rt must r
t must rt must r
t must r
emain at default,emain at default,
emain at default,emain at default,
emain at default,
Attributes 1 and 3 ON.Attributes 1 and 3 ON.
Attributes 1 and 3 ON.Attributes 1 and 3 ON.
Attributes 1 and 3 ON.
Do not prDo not pr
Do not prDo not pr
Do not pr
ogram any PGM output other than PGM2 for 2-wirogram any PGM output other than PGM2 for 2-wir
ogram any PGM output other than PGM2 for 2-wirogram any PGM output other than PGM2 for 2-wir
ogram any PGM output other than PGM2 for 2-wir
e smoke detector suppore smoke detector suppor
e smoke detector suppore smoke detector suppor
e smoke detector suppor
t.t.
t.t.
t.
Refer to the Hook-Up diagram in this manual for wiring instructions
(See Section 2.9.5 “Fire Zone Wiring - 2-Wire
Smoke Detectors”)
.
[05] Partition/System Armed Status The output will activate when the Partition or System is armed and
deactivate when disarmed.
[06] Ready Output The output will activate when the Partition or System is ready to arm. The output will
deactivate when the system is not secure or upon arming.
[07] Keypad Buzzer Follow The output will activate when any of the following events occur and will remain
active for as long as the keypad buzzer is active:
• Door Chime • Entry Delay • Audible Exit Delay
• Auto-Arm Prealert • 24 Hour Supervisory Buzzer Zone
[08] Courtesy Pulse Upon arming the output will activate for the duration of the exit delay plus two minutes. Upon
entry the PGM output will activate for the duration of the entry delay plus two minutes. If more than one courtesy pulse
output is required, they all must be programmed for global operation (PGM attributes 1 and 2 enabled).
[09] System Trouble Output The output will activate when any of the selected trouble conditions are present.
It will deactivate when all the selected trouble conditions are cleared.
The PGM attributes for this option, programmed in Sections [141] to [142], differ from the standard selection of
attributes. Program which trouble conditions will activate the output by selecting some or all of the following
attributes:
[1] .. Service Required [3] .. Telephone Line Trouble [6] .. Zone Tamper
(battery, bell, general trouble, [4] .. Failure to Communicate [7] .. Zone Low Battery
general tamper, general supervisory) [5] .. Fire Trouble / Zone Fault [8] .. Loss of Clock
[2] .. AC Failure
[10] Latched System Event (Strobe Output) The output will activate when any of the selected system events (alarms)
occur on the system. In the armed state, the output will deactivate only once the system is disarmed.
If an alarm activates this output in the disarmed state, the output will deactivate if a user enters a valid access
code while the Bell Cut-off timer is counting down. The output will also deactivate if someone arms the system
after the Bell Cut-off has expired. This output can be used to indicate that an alarm has occurred before entering
the premises.
The PGM attributes for this option, programmed in Sections [141] to [154], differ from the standard selection of
attributes. Program which events will activate the output by selecting some or all of the following attributes:
[1] ...... Burglary (Delay, Instant, Interior, Stay/Away and 24 Hour Burglary Zones)
[2] ...... Fire (Fire Keys, Fire Zones)
[3] ...... Panic (Panic Keys and Panic Zones)
[4] ...... Medical (Auxiliary Keys, Medical and Emergency Zones)
[5] ...... Supervisory (Supervisory, Freezer and Water Zones)
[6] ...... Priority (Gas, Heat, Sprinkler and 24 Hour Latching Zones)
[7] ...... Holdup (Holdup zones)
[8] ...... Output follows pulse timer (Section [164])
This output will activate for silent and audible alarThis output will activate for silent and audible alar
This output will activate for silent and audible alarThis output will activate for silent and audible alar
This output will activate for silent and audible alar
ms or medical conditions onlyms or medical conditions only
ms or medical conditions onlyms or medical conditions only
ms or medical conditions only
. It will not activate. It will not activate
. It will not activate. It will not activate
. It will not activate
during prduring pr
during prduring pr
during pr
e-alere-aler
e-alere-aler
e-aler
t or delays.t or delays.
t or delays.t or delays.
t or delays.
[11] System Tamper
The output will activate when any Tamper condition is present and will deactivate when
all Tamper conditions are cleared.
[12] TLM and Alarm
The output will activate when a telephone line fault condition is present AND an alarm
occurs. The output will remain active until an access code is entered. The output will activate for both audible
and silent alarms if a TLM trouble is present.
This output will activate for all audible and silent alarThis output will activate for all audible and silent alar
This output will activate for all audible and silent alarThis output will activate for all audible and silent alar
This output will activate for all audible and silent alar
ms except Durms except Dur
ms except Durms except Dur
ms except Dur
ess.ess.
ess.ess.
ess.
[13] Kissoff The PGM Output will activate for two seconds after the panel receives the kissoff from the central station.
[14] Ground Start
The output will activate for two seconds before the panel attempts to dial to obtain dial tone
on Ground Start telephone equipment. Two second pauses should be inserted at the beginning of the phone
number when using this option.