DSC Power832 PC5O15 Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
18
[367] System Maintenance Alarms and Restores (Section 5.3 “Communicator – Dialing”)
Default Option ON OFF
ON I________I
11
11
1 1st Telephone Number Disabled
OFF I________I
22
22
2 2nd Telephone Number Disabled
OFF
I________I
33
33
3 1st Telephone Number (via LINKS) Disabled
OFF
I________I
44
44
4 2nd Telephone Number (via LINKS) Disabled
OFF
I________I
5-85-8
5-85-8
5-8 For Future Use
[368] System Test Transmissions
(Section 5.3 “Communicator – Dialing”)
Default Option ON OFF
ON
I________I
11
11
1 1st Telephone Number Disabled
OFF
I________I
22
22
2 2nd Telephone Number Disabled
OFF
I________I
33
33
3 1st Telephone Number (via LINKS) Disabled
OFF
I________I
44
44
4 2nd Telephone Number (via LINKS) Disabled
OFF
I________I
5-85-8
5-85-8
5-8 For Future Use
NOTE: The LINKS backup call directions will only backup their respective phone number.
[370] Communication Variables
Default Section
003
I_______I_______I_______I Swinger Shutdown (Alarms and Rest) (000-255 Transmissions, 000=disabled) 5.17
003
I_______I_______I_______I Swinger Shutdown (Tampers and Rest) (000-255 Transmissions, 000=disabled) 5.17
003
I_______I_______I_______I Swinger Shutdown (Maint and Rest) (000-255 Transmissions, 000=disabled) 5.17
000
I_______I_______I_______I Transmission Delay Time (000-255 seconds) 5.7.1
030
I_______I_______I_______I AC Failure Communication Delay (000-255 minutes) 5.7.5
003
I_______I_______I_______I TLM Trouble Delay
(No. of checks required +3... 000-255 x 10s) 5.11
030 I_______I_______I_______I Test Transmission Cycle (land line) (000-255 days) 5.13
030 I_______I_______I_______I Test Transmission Cycle (LINKS) (000-255 days) 5.13
007
I_______I_______I_______I Zone Low Battery Transmission Delay (000-255 days) 5.7.2
030
I_______I_______I_______I Delinquency Transmisison Cycle (000-255 hours/days) 5.7.4
NOTE: To disable the AC failure communications delay, program [000].
[371] Test Transmission Time of Day (Section 5.13 “Test Transmission”)
Default: 9999
I_______I_______I_______I_______I (Valid entries are 0000-2359, 9999 to disable)
[380] First Communicator Option Code
Default Option ON OFF Section
ON I_______I
11
11
1 Communications Enabled Disabled 5.3
OFF
I_______I
22
22
2 Restorals on Bell Time-out Restorals Follow Zones 5.7.6
OFF
I_______I
33
33
3 Pulse Dialing DTMF Dialing 5.3
ON
I_______I
44
44
4 Switch to Pulse Dialing on 5th Attempt DTMF Dial For All Attempts 5.3
OFF
I_______I
55
55
5 3rd Phone Number enabled Disabled 5.4
OFF
I_______I
66
66
6 Alternate Dial (1st and 3rd) Call 1st Number, Backup to 3rd 5.4
OFF
I_______I
77
77
7 Call LINKS as well as Land Line LINKS is Backup of Land Line(s) 5.26
OFF
I_______I
88
88
8 Activity Delinquency Closing Delinquency 5.7.4
[381] Second Communicator Option Code
Default Option ON OFF Section
OFF
I_______I
11
11
1
Open After Alarm Kypd Ringback Enabled
Disabled 5.20
OFF
I_______I
22
22
2 Open After Alarm Bell Ringback Enabled Disabled 5.20
OFF
I_______I
33
33
3 SIA Sends Programmed Rep. Codes SIA Sends Automatic Rep. Codes 5.6
OFF
I_______I
44
44
4 Closing Confirmation Enabled Disabled 5.20
ON
I_______I
55
55
5 Phone #1/3 Listen-in Enabled Disabled 5.27.1
OFF
I_______I
66
66
6 Phone #2 Listen-in Enabled Disabled 5.27.1
ON I_______I
77
77
7 Contact I.D. Uses Pgm’d Rep. Codes Contact I.D. Uses Automatic Rep. Codes 5.6.2
OFF
I_______I
88
88
8 Local Mode Enabled Disabled P.5, PC5108L
Installation Manual
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Commentaires sur ces manuels

Pas de commentaire