[901] Installer Walk Test Mode Enable/Disable (Section 5.33 “Walk Test [Installer]”)
NOTES:Walk Test should Always be entered from the normal state ([
✱
] [8] [Installer’s Code] [901]).
Fire Troubles are not supported in Walk Test.
Keypad Blanking must be removed before Walk Test can be disabled.
The option “Fire Bell is Continuous”should not be used in Walk Test.
[902] Module Supervision Reset (Section 2.7 “Enable Supervision”)
[903] Module Supervision Field (Section 2.7 “Enable Supervision”)
[904] Wireless Module Placement Test (Section 5.27 “Wireless Expansion”)
• Select the module / transmitter (Zones 01-32).
• Press [#] to Cancel.
Placement Led Keypad LCD Keypad Bell / Buzzer
Good Light 1 ON Steady GOOD 1 Beep / Squawk
Fair Light 2 ON Steady FAIR 2 Beeps / Squawks
Bad Light 3 ON Steady BAD 3 Beeps / Squawks
[906] Local Test of Downlook Remote Trigger
Enter this section to initiate a test of the Downlook Remote Trigger. To tell the panel which telephone number to use
and how to send the remote trigger script, select one of the options below.
[1] Telephone number 1, via landline [3] Telephone number 1, via LINKS
[2] Telephone number 2, via landline [4] Telephone number 2, via LINKS
[990] Installer Lockout Enable (Section 5.32 “Installer Lockout”)
[991] Installer Lockout Disable (Section 5.32 “Installer Lockout”)
[993] Restore LINKS2X50 Factory Default Programming (Section 5.31 “Default [Factory]”)
[995] Restore Escort5580 Factory Default Programming (Section 5.31 “Default [Factory]”)
[996] Restore PC5132 Factory Default Programming (Section 5.31 “Default [Factory]”)
[997] Restore PC5400 Factory Default Programming (Section 5.31 “Default [Factory]”)
[998] Restore PC59XX Factory Default Programming (Section 5.31 “Default [Factory]”)
[999] Restore Factory Default Programming (Section 5.31 “Default [Factory]”)
Special Installer Functions