DSC Power832 PC5O15 Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
6
[008] Maintenance Code (Section 3.1 “Access Codes”)
Default
AAAA I_______I_______I_______I__ _____I
Programmable Output Options
01 Fire and Burglary Output 14 Ground Start Pulse
02 Not used 15 Remote Operation (DLS-1 support)
03 Sensor Reset [][7][2] 16 LINKS1000 Support (PGM 1 only)
04 2-Wire Smoke Support (PGM2 Only) 17 Away Armed Status
05 Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 [][7][1]
07 Keypad Buzzer Follow Mode 20 Command Output #2 [][7][2]
08 Courtesy Pulse 21 Command Output #3 [][7][3]
09 System Trouble Output (with Trouble options) 22 Command Output #4 [][7][4]
10 System Event (with Event options) 23 Silent 24 Hour (PGM2 Only)
11 System Tamper (all sources: zones, keypad, modules) 24 Audible 24 Hour (PGM2 Only)
12 TLM and Alarm 25 Delayed Fire and Burglary Output
13 Kissoff Output
NOTE: PGM output options [03], [04] and [20] cannot be used together on the same system.
[009] PC5015 PGM Output Programming (PGM 1 & 2) (Section 5.10 “PGM Outputs”)
Default
19 I_______I_______I PGM 1
10
I_______I_______I PGM 2
[010] PC5208 PGM Output Programming (PGM 3-10) (Section 5.10 “PGM Outputs”)
Default Default
01 I_______I_______I PGM 3 01 I_______I_______I PGM 7
01
I_______I_______I PGM 4 01 I_______I_______I PGM 8
01
I_______I_______I PGM 5 01 I_______I_______I PGM 9
01
I_______I_______I PGM 6 01 I_______I_______I PGM 10
[011] PC5204 PGM Output Programming (PGM 11-14) (Section 5.10 “PGM Outputs”)
Default
01 I_______I_______I PGM 11
01
I_______I_______I PGM 12
01
I_______I_______I PGM 13
01
I_______I_______I PGM 14
[012] Keypad Lockout Options (Section 5.22 “Keypad Lockout”)
Default
000 I_______I_______I_______I Number of Invalid Codes Before Lockout (enter 000-255)
000
I_______I_______I_______I Lockout Duration (000-255 minutes)
[013] First System Option Code
Default Option ON OFF Section
OFF
I________I
11
11
1 Normally Closed Loops End-of-Line Resistors 2.9
OFF
I________I
22
22
2 Double End-of-Line Resistors Single End-of-Line Resistors 2.9
ON
I________I
3*3*
3*3*
3* Panel Shows All Troubles While Armed Panel Shows Fire Troubles While Armed 3.4
OFF
I________I
44
44
4 Tampers/Faults Do Not Show as Open Tampers/Faults Show as Open 5.25
OFF
I________I
55
55
5 Zone 1 is Fast Loop Response Zone 1 is Standard Loop Response 5.24
ON
I________I
66
66
6 Audible Exit Fault Enabled Disabled 5.15
ON
I________I
77
77
7
Event
Buffer Follows Swinger Shutdown Event Buffer Logs Events Past Shutdown 5.16
OFF I________I
88
88
8 Temporal Three Fire Signal Enabled Standard Pulsed Fire Signal 5.12
* Option 3 must be OFF if LCD5500 keypads older than v2.0 are used.