6
System Outputs (all 12 VDC)
Other Devices
Read the manufacturer’s literature carefully to determine the maxi-
mum current requirement (during activation or alarm) and use this
value for loading calculations. Do not allow connected devices to
exceed the system capabilities during any possible operational mode.
2.6 Assigning Zones to Zone Expanders
The main panel contains zones 1 to 8. Additional zone expanders
may be added to increase the number of zones on the system. Each
zone expander consists of one group of 8 zones. Each module must
be set to assign the specific zones to the expander. To do this, set the
jumpers located on the expander to the proper settings (see chart
below).
NOTE: PC5108 v1.0 and lower modules can only support the first
32 zones on the Power864 system. PC5108 v1.0 and lower, PC5108L,
PC5700, and PC5720 each enroll as two expander modules.
NOTE: Before a zone expander will work properly, you must set the
jumpers so the panel can determine the correct zone assignment.
NOTE: It is not recommended to use Rev01 and Rev02 simulta-
neously on the same Power864.
The following are the jumper settings for different zone assignments
for PC5108 v2.0 modules. If you need to enroll PC5108 v1.0,
PC5108L or PC5700 modules, refer to the appropriate module Instal-
lation Sheet for the correct jumper settings.
The following is a diagrams of the PC5108 zone expander modules and
where the jumper switches are located. Refer to the Installation Instruc-
tion sheet for the module for more information.
NOTE: Only jumpers J1, J2, and J3 determine the zone assignment
for the module
2.7 Keypad Assignment
There are 8 available slots for keypads. LED and LCD5501Z keypads
by default are assigned to slot 1. The LCD5500Z is assigned by
default to slot 8. Keypads can each be assigned to a different slot (1
to 8) which offers two advantages. The panel can supervise the key-
pad connection to indicate a trouble condition if it is removed. Also
keypads can be assigned to operate a specific partition, or to operate
as a global keypad.
How to Assign Keypads
NOTE: All keypad assignment must be done at each keypad on the
system. When using LCD5500(Z) keypads, one keypad must remain in
slot 8. Do not assign more than one keypad to the same slot.
NOTE: The following keypad versions can only be used on the Par-
tition 1 and Partition 2, and the first 8, 16, or 32 zones:
PC5508(Z), PC5516(Z), PC5532(Z) versions v2.00 and lower
LCD5500(Z) versions 3.x and lower. To assign a keypad to a slot and
select the partition it will operate, enter the following:
1. Enter Installer Programming
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot assign-
ment.
1st digit enter 0 for Global operation, or
enter 1-8 for Partitions 1-8
2nd digit enter 1 to 8 for Slot Assignment
5. Press the [#] key twice to exit programming.
6. Continue this procedure at each keypad until all have been
assigned to the correct slot and partition.
How to Program Function Keys
Each of the 5 function keys on each keypad may be programmed for
different operation.
1. Enter Installer Programming.
2. Press [000] for Keypad Programming.
3. Enter [1] to [5] to select function key to program.
4. Enter a 2-digit number for function key option - [00] to [21].
5. Continue from step 3 until all function keys are programmed.
6. Press [#] key twice to exit Installer Programming.
For a complete list of Function Key options, see section 4.3 Function
Keys on page 13.
2.8 Confirming Module Supervision
By default, all modules are supervised upon installation. Supervision
is enabled at all times so that the panel can indicate a trouble if a
module is removed from the system.
To check which modules are currently connected and supervised:
1. Press [*] [8] [Installer Code] to enter Installer Programming.
2. Press [903] to display all modules.
3. The LCD keypad will allow you to scroll through the modules.
NOTE: Module supervision will not display correctly at an
LCD5500Z v2.x and lower keypad.
PC5020 VAUX: 420 mA.
Subtract the listed rating for each keypad, expan-
sion module and accessory connected to VAUX or
Keybus.
BELL: 700 mA.
Continuous Rating.
3.0 A.
Short Term. Available only with stand-by battery
connected.
PC5200 VAUX: 1.0 A.
Continuous Rating. Subtract for each device con-
nected.
3.0 A.
Short Term. Available only with stand-by battery
connected.
PC5204 VAUX: 1.0 A.
Continuous Rating. Subtract for each device con-
nected.
3.0 A.
Short Term. Available only with stand-by battery
connected.
PC5208 VAUX: 250 mA.
Subtract for each device connected. Subtract the
total load on this terminal from the PC5020
VAUX/Keybus output.
PC5108 VAUX: 100 mA.
Subtract for each device connected. Subtract the
total load on this terminal from the PC5020
VAUX/Keybus output.
Module Jumpers
System Zones
Assigned
J1 J2 J3
ON ON ON Zones disabled
OFF ON ON Zones 09 - 16
ON OFF ON Zones 17 - 24
OFF OFF ON Zones 25 - 32
ON ON OFF Zones 33 - 40
OFF ON OFF Zones 41 - 48
ON OFF OFF Zones 49 - 56
OFF OFF OFF Zones 57 - 64
WWW.DIYALARMFORUM.COM