PC5020 Wiring Diagram
NOTE: AUX+ (420mA) is
shared between AUX+,
Keybus and all PGM outputs
WARNING:
Not to be removed
by anyone except occupant.
This equipment should be
installed in accordance with the
National Fire Code ANSI/NFPA
72 (National Fire Protection
Association, Batterymarch Park,
Quincy MA, 02269). Printed
information describing proper
installation, operation, testing,
maintenance, evacuation
planning, and repair service is
to be provided with this
equipment. For compliance with
UL-985, at least one hardwired
smoke detector is required.
(a) The delay (power-up) (start-up) time marked on the
installation wiring diagram of the smoke detector or on the
installed smoke detector(s) is to be used.
All circuits are classified for UL installations as power limited / Class2
power limited, except for the battery leads. Do not route any wiring over
circuit boards. Please see Installation Manual Section 2.3, Installation &
Wiring. A minimum 1/4” (7mm) separation must be maintained at all points
between power limited wiring and all other non power limited wiring.
WARNING
High voltage. Disconnect
AC power and telephone
lines prior to servicing.
APPLICABLE UL STANDARDS
UL FILE NO. S4019
UL1610 Central-Station Burglar-Alarm Units
UL609 Local Burglar Alarm Units and Systems
UL365 Police Station Connected Burglar Alarm
Units & Systems
UL985 Household Fire Warning System Units
UL1023 Household Burglar-Alarm System Units
UL1635 Digital Alarm Communicator System Units
UL1637 Home HealthCare Signaling Equipment
PC5020 Wiring Diagram