18
[005] - System Times
This section has 9 sub-sections, 1 for each of the 8 partitions, and 1
for the Bell timeout. A 2-digit entry is required to access these sub-
sections.
NOTE: Entry of 000 in these sections will result in a 255 second time.
Sub-Sections 1-8 each require three 3-digit entries.
[01] - [08] Entry Delay 1, Entry Delay 2, and Exit Delay per Partition.
• Entry Delay 1: (030-255) Seconds
This value determines the Entry delay time for Delay 1 type zones.
The default Entry Delay 1 time is 30 seconds.
• Entry Delay 2: (030-255) Seconds
This value determines the Entry delay time for Delay 2 type zones.
The default Entry Delay 2 time is 30 seconds.
• Exit Delay: 045-255 Seconds
This value determines the Exit delay time when arming the system.
The default Exit Delay time is 60 seconds.
NOTE: The exit delay must not exceed 255 seonds. The minimum
possible entry is 45 seconds.
NOTE: If the Exit Delay is silent (Section 014, Option 6 or Stay Func-
tion Key Arming) the Exit Delay will be twice the programmed value
(090-510 seconds).
[09] Bell Cut-off: 001-255 Minutes
The Bell Cut-off for all 8 partitions will be the same.
The siren will silence after the number of minutes programmed for the
Bell Cut-off time have passed. The default Bell Cut-off is 4 minutes
The panel supervises the Bell output. If an open condition is
detected, the panel will immediately indicate a trouble condition by
beeping the keypad twice every 10 seconds to alert the owner of the
problem. The panel can send a Bell Circuit Trouble and Trouble
Restoral reporting codes to indicate the situation (See Section 5.6
Communicator Programming PWS Sect 6).
If the Temporal Three Fire Signal option is enabled, all Fire signals
will follow the Temporal Three Pattern as described in NFPA 72. If
turned OFF all Fire signals will sound a one second on, one second
off cadence.
If Fire Bell Continuous is enabled, the alarm output will sound until
a code is entered. If disabled, the alarm will sound until a code is
entered or the bell cut-off time has expired.
NOTE: Only fire zones will follow the Temporal Three Fire Signal.
Bell Cut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [005]
Bell Circuit Trouble Reporting Code . . . . . . . . . . . . . . Section [349]
Bell Circuit Trouble Restoral Reporting Code . . . . . . . Section [350]
Temporal Three Fire Signal
Enable/Disable. . . . . . . . . . . . . . . . . . . . . Section [013], Option [8]
Fire Bell Continuous . . . . . . . . . . . . . . . . Section [014], Option [8]
[006]-[008] Special Access Codes
These sections require 4 or 6 digits to be entered.
24 LINKS Answer Provides the LINKS with a forced answer for downloading. The Restored state of this zone type is 5.6KΩ, and the
open state causes the panel to answer.
NOTE: This zone type must not be used for wireless zones.
25 Interior Delay Zone The Interior Delay Zone is normally used with motion detectors and has a standard exit delay time. If the panel is
armed, and a Delay zone is violated during the Exit Delay (or the Away function key is used), the Interior Delay Zone
will be active at the end of the Exit Delay. This zone will cause an instant alarm when violated. This zone type will fol-
low the Entry Delay time provided that a Delay zone is violated first. If the panel is armed, and a Delay zone is NOT
violated during the Exit Delay (or the Stay function key is used, or [*][9] armed), a violation of this zone type will ini-
tiate Entry Delay 1.
26 24 Hour Non-Alarm These zones are active at all times but do not cause an alarm, and do not show up in alarm memory. Zone Attributes
such as Zone Bypassing and Door Chime affect the functionality of this zone. A 24 Hour Non-alarm zone may be
used for Zone Follower automation applications.
NOTE:This zone type will be active in Walk Test. Tampers and Faults. Zones programmed as 24 Hour Non-alarm
type will not cause alarms.
NOTE: Alarms on this zone will not initiate Downlook.
27 Delayed 24Hr Water-
flow*
These zones will follow the waterflow Delay Timer. When a delayed waterflow zone is violated, the waterflow timer
will start, (any subsequent delayed waterflow zones that become active do not reset or abort this timer). If there are
still delayed waterflow zones open when the waterflow timer expires, the panel will go into alarm and communicate
the event(s) regardless of the armed state.
28 Instant 24Hr Water-
flow*
A Waterflow alarm is a Fire alarm. The Fire related bells and Aux functions are activated. This Zone type functions
similar to Type 27 (Delayed 24Hr Water-flow), but does not follow the Water-flow Delay Timer. When this zone is
violated, it will immediately go into alarm. This zone type always uses a single EOL configuration.
29 Auto Verified Fire Zone This zone ensures that an alarm condition persists by resetting a tripped sensor in a fire zone and confirming that the
sensor has remained tripped or is waiting for the sensor to re-trip within a set period of time. (e.g. Cycling power to
a smoke detector to ensure the condition persists when power is restored.) The alarm sequence for the zone is indi-
cated below:
Step #1 Duration 20 Seconds Sensor Reset
Step #2 Duration 10 Seconds Settle Time (Power Up)
Step #3 Duration 60 Seconds Check for Verified Alarm
NOTE: If another Fire device detects Fire during the Auto Verify or Delay sequence, the sequence is terminated and
alarms are immediately generated for all pending zones. This applies to all other Fire zones on the system regardless
of the partition assignments (i.e. two fire alarms anywhere on the system will cancel all pending fire delays and cre-
ate immediate alarms).
30 Fire Supervisory Zone When this zone is violated, the system turns on the keypad buzzer, and communicates the supervisory alarm condi-
tion to the monitoring station. The buzzer will not follow the Bell-Time-Out timer. To silence the buzzer, a valid
access code must be entered.
NOTE: The fire supervisory alarm is not affected by the water-flow silence inhibit option described in [018], Option
4, Pg 32
31 Day Zone A zone programmed with this type has different characteristics in the armed and disarmed state. In the disarmed
state, violating this zone will sound the keypad buzzer but will not log or report the event. In the armed state, violat-
ing this zone will sound the bell and communicate the event..
87 Delayed 24 Hour Fire
(Wireless)
Used only with wireless smoke detectors. Functions same as that of Zone Type [07].
88 Standard 24 Hour Fire
(Wireless)
Used only with wireless smoke detectors. Functions same as that of Zone Type [08].
[001]-[004] ZONE DEFINITIONS
Option Zone Type Description
* Not verified by UL