2
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Urgency on Entry Delay
Quick Exit
Swinger Shutdown
Recent Closing Transmission
Cross Zone Alarm
Burglary-verified timer
Double Hit Timer
Communication Delay
Rotating Keypress Buffer
Additional Features
Automatic arming by partition at a specified time, each day of
the week
Keypad activated alarm output and communicator test
Keypad lockout
Audio capability using the PC5936 Audio Interface Module,
allows local intercom and central station 2-way listen-in
All modules connect to the system via a four wire Keybus, up to
1000’/305m from the main panel
Event buffer can be printed using PC5400 RS-232 Serial Interface
module
Supports the Escort5580 Voice Prompt Module, with automation
and lighting control
256 event buffer, time and date stamped
Uploading/downloading capability
Daylight savings time option
Downlook support (DLM-4L v1.0 and PC5108L)
1.4 Additional Devices
In addition to the information below, see the back cover for a DSC
Module Compatibility table.
Keypads
A maximum of 8 keypads can be connected to the control panel.
You can connect any combination of the following listed. Different
keypads (with function keys) can be used for different size systems: 8
zone, 16 zone, 32 zone, and 64 zone.
PC5508Z: 8 zone LED keypad, with one zone input
PC5532Z: 32 zone LED keypad, with one zone input
PC5516Z: 16 zone LED keypad, with one zone input
LCD5500Z: LCD keypad, with one zone input
LCD5501Z: LCD-style keypad, with one zone input
NOTE: The following keypad versions can only be used on the first
two partitions (Partition 1 and Partition 2), and the first 8, 16, or 32
zones:
PC5508(Z), PC5516(Z), PC5532(Z) versions v2.00 and lower
LCD5500(Z) versions 2.x and lower
LCD5501Z versions 1.x and lower
PC5100 2-Wire Addressable Device Interface Module
The PC5100 module is used to connect 2-wire addressable devices to
the system. Up to 32 2-wire addressable devices can be added to the
system
NOTE: PC5100 v1.0 and lower modules can only support the first
32 zones on the Power864 system.
PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the number of
zones on the system. Up to 7 modules can be connected to increase
the system zones to a maximum of 64. (See the PC5108 Installation
Instructions Sheet.)
NOTE: PC5108 v1.0 and lower modules can only support the first
32 zones on the Power864 system. PC5108 v1.0 and lower modules
enroll as two modules and use up two supervisory slots.
NOTE: Do not mix PC5108 v1.x and lower modules with PC5108
v2.0 and higher modules on the same system.
PC5132 Wireless Receiver Module
The PC5132 Wireless Receiver module can be used to connect up to
32 fully supervised wireless devices. (See the PC5132 Installation
Manual for details.)
NOTE: Only the first 32 zones on the Power864 system can be
used as wireless zones.
PC5200 Power Supply Output Module
The PC5200 can provide up to 1 Amp of additional power for mod-
ules or devices connected to the control panel. Up to 4 modules can
be connected to the system. Each module requires a 16.5 volt AC 40
VA transformer and 4 AH battery. (See PC5200 Installation Instruc-
tions for details.)
PC5204 Power Supply Output Module
The PC5204 can provide up to 1 Amp of additional power for mod-
ules or devices connected to the control panel. The module requires
a 16.5 volt AC 40 VA transformer and 4 AH battery. In addition, the
module provides 4 programmable high current voltage outputs. (See
PC5204 Installation Instructions for details.)
PC5208 Eight Low Current Output Module
Adds eight programmable low current outputs (50 mA) to the con-
trol. (See the PC5208 Installation Instructions for details.)
NOTE: If you use the main panel and the PC5208 outputs, PGM 3
will work the same as the first PC5208 output, and PGM 4 will work
the same as the second PC5208 output.
Escort5580 Module
This Escort5580 module will turn any touch-tone telephone into a
fully functional keypad. The module also includes a built-in interface
to control up to 32 line carrier type devices for lighting and tempera-
ture control (See the Escort5580 Installation Manual for details.)
NOTE: Users will not be able to access partitions 3 to 8, and zones
33 to 64 through Escort5580 versions 2.x and lower. Only partitions
1 and 2, and zones 1 to 32 are supported on these versions.
PC5936 Audio Interface Module
The PC5936 Audio Interface modules provide paging, intercom,
baby listen-in and door answer to the PC5020 control panel. The
modules have built-in two-way voice capability for central station
(See the PC5936 Installation Manuals for details).
Three additional devices are available:
PC5921 Intercom Audio Station can be used in conjunction with
the PC5936 Audio Interface Module.
PC5921 EXT Door Box Audio Station can be used in conjunction
with the PC5936 Audio Interface Module.
PC5921 EXT/R Door Box Audio Station can be used in conjunction
with the PC5936 Audio Interface Module. The Door Box contains a
relay so the normal door bell can be used instead of the internal
one generated by the PC5936 Audio Interface Modules.
PC5400 Printer Module
This PC5400 Printer Module will allow the panel to print out all
events that occur on the system to any serial printer. All events will
be printed with the Partition, time, date and the event that occurred.
(See PC5400 Installation Manual for details.)
NOTE: The PC5400 v2.x and lower only supports events on parti-
tions 1 and 2, and zones 1-32.
LINKS1000 Cellular Communicator
The LINKS1000 Cellular Communicator provides an efficient, cost-
effective method for adding cellular back up. The unit comes in its
own cabinet with antenna and requires a separate battery and trans-
former (See Links1000 Cellular Communicator in Section 5).
Alternate Communicators
Refer to the associated installation manual for LINKS2X50,
LINKS3000, and Skyroute™ programming details.
Downlook Support: PC5108L and DLM-4 v1.0L
The PC5108L will expand the control panel’s zone capability by add-
ing eight fully programmable zone inputs. The module will also act
as an interface between the DLM-4L v1.0 Video Transmission module
and the PC5020 control panel. The PC5108L is also an 8-camera
video switcher.